Trane 4TEP3F18A1000A Installer's Manual page 6

Convertible air handlers 1-1/2 - 5 tonf or r-410a
Table of Contents

Advertisement

|nsta||er's
Guide
®
i
3/4 NPT Secondary
drain connection
3/4" NPT
Primary drain
connection
©
MANUFACTURED
TRAPS
2" MINIMUM
r
=
2" MINIMUM
EZT-105
(_
FIELD FABRICATED
TRAP
2" lVllN.
I
I
m
=,
I
2" Mid
,I
I
I
I
I
I
Close as possible
Trap must be within 4'
[
of air handler condensate
J
drain connection.
5. Slope the drain
lines downward
a minimum
of 1/4"
per foot.
6. Insulate
the primary
drain
to prevent
sweating.
7. Provide
means
for drainage
to prevent
winter
freeze-up
of condensate
line.
8. Do not connect
the drain
line to a closed drain
system.
9. Use Teflon ® tape
on the air handler
drain
line
connections!
Do Not Use pipe joint
compound
or
PVC/CPVC
cement!
It is always recommended
that an auxiliary drain pan be
installed
under a horizontally
installed
air handler.
Connect the auxiliary drain line to a separate
drain line
(no trap is needed in this line) and terminate
according to
local codes.
NOTE:
DO NOT use a torch or flame near the plastic
drain pan
coupling.
NOTE:
DO NOT tighten
the drain pipe excessively.
Support the
condensate
piping
and traps outside
the unit to prevent
strain on the drain coupling.
TO PREVENT INJURY OR DEATH DUE TO ELECTRICAL
SHOCK OR CONTACT WITH MOVING PARTS, LOCK
UNIT DISCONNECT
SWITCH IN OPEN POSITION
[BEFORE SERV C NG UN T.
F=
1.
ELECTRICAL
m POWER WIRING
These Air Handlers
are shipped from the factory
wired for 230 volts. The units may be wired for 208
volts. Follow instructions
on unit wiring diagram
located on blower housing and in the Service Facts
document
included with the unit.
2. The selection of wire and fuse sizes should be made
according to the Minimum Branch Circuit Ampacity
and the Maximum Overcurrent
Device listed on the
unit nameplate.
3. Field wiring diagrams for electric heaters
and unit
accessories
are shipped with the accessory.
4. Wiring must conform to National
and Local codes.
Ground
unit per Local codes with good safety
procedures.
If an electric heater is not installed, connections are made
through the 7/8" knockout into the air handler junction
box to the two power leads and ground wire connections
which are located near the discharge
of the blower.
NOTE:
ff air handler is used with or without a heater, the 7/8"
electrical
entry hole as weft as any other cabinet penetra-
tions must be sealed air ti hghL.
6
18-G E02D2-4