Fireproofing pump electric sprayer for water-based cementitious fireproofing materials. for professional use only. not approved for use in exploisive atmospheres or hazardous locations (54 pages)
1:1 ratio pump, air-operated piston transfer pump for low viscosity fluids. (38 pages)
Summary of Contents for Graco Fireball 225
Page 1
300 Portable Gear Lube Pump For dispensing fluid in stationary or mobile installations. For professional use only. Model 246903 – 3:1 Fireball 225 Pump 540 psi (3.7 MPa, 37 bar) Maximum Working Pressure Model 225728 – 5:1 Fireball 300 Pump 900 psi (6.2 MPa, 62 bar) Maximum Working Pressure...
Page 2
D Read all instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor. D Do not alter or modify this equipment. Use only genuine Graco parts and accessories.
Page 3
WARNING WARNING INJECTION HAZARD High pressure fluid from dispense device, hose leaks or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment. D Do not point the dispensing device at anyone or at any part of the body.
WARNING WARNING MOVING PARTS HAZARD Moving parts can pinch or amputate your fingers. D Keep clear of all moving parts when starting or operating the pump. D Before servicing the equipment, follow the Pressure Relief Procedure on page 8 to prevent the equipment from starting unexpectedly.
Page 5
Installation The typical installation shown in Fig. 2 is only an installation guide; it is not an actual system design. Contact your Graco distributor for assistance in designing a system to suit your needs. Fluid dispense line Pump ground wire...
Installation Air and Fluid Line Accessories D Install an air line lubricator (F) for automatic air NOTE: Install the accessories in the order shown in Fig. 2 on page 5. motor lubrication. CAUTION To order a 250 psi (1.74 MPa, 17.4 bar) maximum working pressure air line lubricator, order a Part No.
Page 7
Installation Dispense Kit (Parts 2a and 2b) Connect the hose (2a) to the pump outlet. Connect the dispense valve (2b) to the hose (2a). Air Regulator Kit (Parts 5a – 5d) Fluid hose Dispense valve Regulator, air, 3/8 npt (f) 0–250 psi (17.4 bar) Gauge, air pressure Valve, air bleed–type 3/8 npt (f) Nipple, 3/8 npt...
Operation Pressure Relief Procedure 1. Close the pump air regulator. WARNING 2. Close the pump’s bleed-type master air valve (required in the system). INJECTION HAZARD To reduce the risk of serious bodily 3. Hold a metal part of the gun or valve firmly to a injury, including fluid injection, injury from grounded metal waste container and trigger to moving parts, or splashing in the eyes or...
Page 9
Operation Startup 4. Set the air pressure to each pump at the lowest WARNING pressure needed to get the desired results. Use the regulator to adjust pump speed and pressure. The maximum working pressure of each pump in your system may not be the same. To reduce the CAUTION risk of overpressurizing any part of your system, be sure you know the maximum working pressure rat-...
Parts Drawing Model 246903 3:1 Ratio Fire-Ball 225 Portable Gear Lube Pump with Drum Cover Model 225728 5:1 Ratio Fire-Ball 300 Portable Gear Lube Pump Dispense Kit with Drum Cover includes items 5a – 5d (5d not shown) Dispense Kit includes items 2a and 2b 307884...
Parts Lists Model 246903 3:1 Ratio Fire-Ball 225 Portable Gear Lube Pump with Drum Cover Model 225728 5:1 Ratio Fire-Ball 300 Portable Gear Lube Pump with Drum Cover Ref. No. 2 Ref. No. Part No. Description Qty. Dispense Kit 237075, Series B 248097 PUMP, 3:1 Ratio Fire-ball;...
Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.