National Instruments 9229 Getting Started Manual
National Instruments 9229 Getting Started Manual

National Instruments 9229 Getting Started Manual

4 ai, ±60 v, 24 bit, 50 ks/s/ch simultaneous

Advertisement

Quick Links

GETTING STARTED GUIDE
NI 9229
4 AI, ±60 V, 24 Bit, 50 kS/s/ch Simultaneous

Advertisement

Table of Contents
loading

Summary of Contents for National Instruments 9229

  • Page 1 GETTING STARTED GUIDE NI 9229 4 AI, ±60 V, 24 Bit, 50 kS/s/ch Simultaneous...
  • Page 2: Safety Guidelines

    This document explains how to connect to the NI 9229. Before you begin, complete the software and Note hardware installation procedures in your chassis documentation. The guidelines in this document are specific to Note the NI 9229. The other components in the system might not meet the same safety ratings.
  • Page 3 1,390 V, verified by a 5 s dielectric withstand test Channel-to-earth ground Continuous 250 Vrms, Measurement Category II Withstand 2,300 V, verified by a 5 s dielectric withstand test NI 9229 Getting Started Guide | © National Instruments | 3...
  • Page 4 Measurement Categories CAT II, CAT III, or CAT IV. If using in Division 2 or Zone 2 hazardous Caution locations applications, do not connect the NI 9229 with Channel-to-channel and channel-to-earth ground 4 | ni.com | NI 9229 Getting Started Guide...
  • Page 5 NI 9229 with BNC Safety Voltages Connect only voltages that are within the following limits: Isolation Channel-to-channel Continuous 60 VDC, Measurement Category I Withstand 1,000 V, verified by a 5 s dielectric withstand test NI 9229 Getting Started Guide | © National Instruments | 5...
  • Page 6 Measurement Categories CAT I and CAT O are Note equivalent. These test and measurement circuits are not intended for direct connection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV. 6 | ni.com | NI 9229 Getting Started Guide...
  • Page 7: Safety Guidelines For Hazardous Voltages

    Ensure that devices and circuits connected to Caution the module are properly insulated from human contact. When module terminals are hazardous Caution voltage LIVE (>42.4 Vpk/60 VDC), you must ensure NI 9229 Getting Started Guide | © National Instruments | 7...
  • Page 8: Safety Guidelines For Hazardous Locations

    Safety Guidelines for Hazardous Locations The NI 9229 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2, AEx nA IIC T4 and Ex nA IIC T4 hazardous locations; and nonhazardous locations only.
  • Page 9 Special Conditions for Hazardous Locations Use in Europe and Internationally The NI 9229 has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO Certificate No. 07 ATEX 0626664X and is NI 9229 Getting Started Guide | © National Instruments | 9...
  • Page 10 Zone 2 hazardous locations, in ambient temperatures of -40 °C ≤ Ta ≤ 70 °C. If you are using the NI 9229 in Gas Group IIC hazardous locations, you must use the device in an NI chassis that has been evaluated as Ex nC IIC T4, Ex IIC T4, Ex nA IIC T4, or Ex nL IIC T4 equipment.
  • Page 11: Electromagnetic Compatibility Guidelines

    Furthermore, any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules. NI 9229 Getting Started Guide | © National Instruments | 11...
  • Page 12: Cable Requirements For Emc Compliance

    Refer to the NI 9229 product page on ni.com purchasing information about clamp-on ferrite beads. Cable Requirements for EMC Compliance Select and install cables for the NI 9229 with BNC in accordance with the following requirements: • Install a clamp-on ferrite bead (NI part number 782801-01) on the BNC cable for each channel that you are connecting to on the NI 9229 with BNC.
  • Page 13: Special Conditions For Marine Applications

    LR certificate, or look for the Lloyd’s Register mark on the product. In order to meet the EMC requirements for Caution marine applications, install the product in a shielded NI 9229 Getting Started Guide | © National Instruments | 13...
  • Page 14: Preparing The Environment

    EMC performance is attained. Preparing the Environment Ensure that the environment in which you are using the NI 9229 meets the following specifications. Operating temperature -40 °C to 70 °C...
  • Page 15 NI 9229 Pinout AI0+ AI0+ AI0– AI0- AI1+ AI1+ AI1– AI1- AI2+ AI2+ AI2– AI2- AI3+ AI3+ AI3– AI3- NI 9229 Getting Started Guide | © National Instruments | 15...
  • Page 16: Grounded Connections

    Negative analog input signal connection Grounded Connections Signal Source – AI– NI 9229 Make sure the voltage on the AI+ and AI- connections are in the channel-to-earth safety voltage range to ensure proper operation. 16 | ni.com | NI 9229 Getting Started Guide...
  • Page 17: Floating Connections

    AI– NI 9229 NI 9229 Connection Guidelines • Make sure that devices you connect to the NI 9229 are compatible with the module specifications. • You must use 2-wire ferrules to create a secure connection when connecting more than one wire to a single terminal on the NI 9229 with screw terminal.
  • Page 18: Wiring For High-Vibration Applications

    Use ferrules to terminate wires to the detachable connector. • Use the NI 9971 backshell kit. Overvoltage Protection The NI 9229 provides overvoltage protection for each channel. Refer to the device datasheet on ni.com/manuals Note for more information about overvoltage protection.
  • Page 19: Where To Go Next

    NI 9229 Datasheet NI-RIO Help NI-DAQmx Help LabVIEW FPGA Help LabVIEW Help RELATED INFORMATION C Series Documentation Services & Resources ni.com/services ni.com/info cseriesdoc Located at ni.com/manuals Installs with the software NI 9229 Getting Started Guide | © National Instruments | 19...
  • Page 20: Worldwide Support And Services

    (EMC) and product safety. You can obtain the DoC for your product by visiting ni.com/certification. If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration. 20 | ni.com | NI 9229 Getting Started Guide...
  • Page 21 United States, visit the Worldwide Offices section of ni.com/niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, email addresses, and current events. NI 9229 Getting Started Guide | © National Instruments | 21...
  • Page 22 U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. © 2007—2016 National Instruments. All rights reserved. 374184N-01 Mar16...