Repairing The Advanced Display Module; (Adm) - Graco ProMix PD2K Repair Parts

Proportioner for automatic spray applications
Hide thumbs Also See for ProMix PD2K:
Table of Contents

Advertisement

Repair
Repairing the Advanced Display Module (ADM)
Replace the ADM
To replace the Advanced Display Module, disconnect
the cable from the module and remove the module
from the bracket. Install the new module on the
bracket and attach the cable.
Figure 26 Replace the Advanced Display Module
Install Key Token or Upgrade Token
1. Shut off the PD2K power switch.
2. Remove the token access panel.
Figure 27 Remove Token Access Panel
3. Remove blue key token.
4. Insert and press black upgrade token (T) firmly
into slot.
NOTE: There is no preferred orientation of the
token.
Figure 28 Insert Token
50
5. Turn the power switch back on. The red indicator
light (L) will flash until the new firmware is
completely loaded.
6. Remove the token (T).
7. Replace the blue key token.
NOTE: The blue key token is required for proper
operation.
8. Replace the token access panel.
Replace the Battery
A lithium battery maintains the ADM clock when the
power is not connected.
Sparking can occur when changing the battery. To
reduce the risk of fire and explosion, replace the
battery only in a non-hazardous location, away
from flammable fluid or fumes.
1. Turn off the PD2K power switch.
2. Remove the rear access panel.
Figure 29 Remove Battery Panel
3. Remove the old battery and replace with a new
CR2032 battery.
4. Replace the rear access panel.
5. Turn the power switch on.
6. Dispose of the old battery according to your
federal, state, and local waste regulations.
332709D

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ac0500Ac0502Ac1000Ac1002Ac2000Ac2002

Table of Contents