Repair; Before Servicing - Graco ProMix PD2K Repair Parts

Proportioner for automatic spray applications
Hide thumbs Also See for ProMix PD2K:
Table of Contents

Advertisement

Repair

Repair

Before Servicing

Servicing the electrical control box exposes you to
high voltage. To avoid electric shock;
• Turn off power at the main circuit breaker before
opening the enclosure.
• All electrical wiring must be done by a qualified
electrician and comply with all local codes and
regulations.
• Do not substitute or modify system components
as this may impair intrinsic safety.
NOTICE
To avoid damaging the circuit boards when
servicing the control box, wear Part No. 112190
grounding strap on your wrist and ground
appropriately.
To avoid electrical component damage, remove all
system power before plugging any connectors.
48
1. Flush the system as explained in your
PD2K Operation Manual if service time
may exceed pot life time. Follow the
Pressure Relief Procedure, page 49
servicing fluid components.
2. Close the main air shutoff valve on the air supply
line.
3. Shut off the power switch (P) at the electrical
control box.
4. If servicing the electrical control box, shut off
power at the main circuit breaker before opening
the enclosure.
Figure 25 Control Box Power Switch
before
332709D

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ac0500Ac0502Ac1000Ac1002Ac2000Ac2002

Table of Contents