Using two 1/4-20 x 1" bolts and nuts, attach the draft blower adapter
to the draft tube on the front of the furnace. Th en mount and secure
the draft blower to the adapter with the three 10-24 Kep nuts. Plug
the blower into the outlet on the front of the furnace.
(1) Draft Blower
(1) Draft Blower Adapter
(2) 1/4-20 x 1 Hex Bolt
(2) 1/4-20 Lock Nut
(3) 10-24 Kep Nut
FIREBOX BRICK REPLACEMENT
Th is furnace comes from the factory with the fi rebrick in-
stalled. However, if brick replacement is necessary, follow these
instructions. Before furnace operation, remove the brick re-
taining strip. Th is piece is used during shipping to reduce brick
damage.
For model 1602, there are 6 full brick and 1 half brick per side.
Install the half brick fi rst by putting the bottom of the brick in
fi rst and let it rest against the fi rebox side and fi re grates. Th en
slide it to the rear. Aft er that, install the #2, #3, #4, #5 & #6
brick, sliding the 6th brick forward to allow for the 7th brick.
Repeat for opposite side.
For model 1802, there are 8 full brick and 1 half brick per side.
Install the brick in the same manner as previously instructed
for the model 1602.
NOTE: Prior to operation, be sure to remove the brick retain-
ing strips.
FORCED DRAFT BLOWER - 69189
FIREBRICK AND BAFFLE REPLACEMENT
BAFFLE/BRICK REPLACEMENT
If baffl e replacement is necessary, slide the baffl e out until you
can access the nuts thru the fl ue outlet. Once the nuts have
been removed, slide the baffl e off the rod and thru the opening
in the fi rebrick. You may have to remove one of the fi rebrick to
make baffl e removal easier.
For model 1602, there are 4 full brick and 1 half brick in the
top of the furnace. Install the brick by inserting one end of the
brick angled upward and then allowing the opposite end to rest
on the fi rebox lip. Lay the brick between the spacer and fi rebox
back. Slide the baffl e to the rear and let it rest on that half brick.
Aft er installing brick #2 in the front, install #3 and slide it un-
der the baffl e. Finally install bricks #4 and #5.
For model 1802, there are 6 full brick in the top of the furnace.
Install the brick in the same manner as previously instructed
above.