Paradyne COMSPHERE 3000 Series Installation Manual page 17

Carrier
Hide thumbs Also See for COMSPHERE 3000 Series:
Table of Contents

Advertisement

COMSPHERE 3000 Series Carrier
Technical Specifications for the COMSPHERE 3000 Series Carrier
Technical Specifications
POWER REQUIREMENTS (Cont'd)
Shared Diagnostic Unit (SDU)
Model 3151
Model 3161
Model 3511
Models 3551 and 3611
DBM-V, DBM-S, or DBM-D
Models 3551, 3611, and 3616 with DBM
Model 3611 with TDM
Model 3611 with DBM and TDM
Model 3611 with MCMP
Model 3611 with DBM and MCMP
Model 3811 modem
Model 3911 modem
Carrier with sixteen 3551, 3611, and 3616
DSUs with DBMs plus SDU and fan module
Carrier with sixteen 3151 CSUs plus SDU,
SDCP, and fan module
Carrier with sixteen 3161 DSU/CSUs plus
SDU, SDCP, and fan module
FAN MODULE POWER DISSIPATION
100 Vac
115 Vac
230 Vac
1-4
Table 1-1
(2 of 6)
Criteria
24 Vac (CT), 60 Hz 3 (0.01 amp, 1.5 watts at 115 Vac)
24 Vac (CT), 60 Hz 3 (3.7 watts at 115 Vac)
24 Vac (CT), 60 Hz 3 (9.3 watts at 115 Vac)
24 Vac (CT), 60 Hz 3 (0.07 amp, 6 watts at 115 Vac)
24 Vac (CT), 60 Hz 3 (0.03 amp, 4.5 watts at 115 Vac)
24 Vac (CT), 60 Hz 3 (0.05 amp, 8.0 watts at 115 Vac)
24 Vac (CT), 60 Hz 3 (0.05 amp, 8.0 watts at 115 Vac)
24 Vac (CT), 60 Hz 3 (0.07 amp, 8.6 watts at 115 Vac)
24 Vac (CT), 60 Hz 3 (0.09 amp, 12.15 watts at 115 Vac)
24 Vac (CT), 60 Hz 3 (0.08 amp, 9.1 watts at 115 Vac)
24 Vac (CT), 60 Hz 3 (0.10 amp, 12.65 watts at 115 Vac)
24 Vac (CT), 47— 63 Hz (0.05 amp, 3.4 watts at 100 Vac)
24 Vac (CT), 60 Hz 3 (0.04 amp, 3.4 watts at 115 Vac)
24 Vac (CT), 47— 63 Hz (0.02 amp, 3.4 watts at 230 Vac)
24 Vac (CT), 47— 63 Hz (0.07 amp, 4.0 watts at 100 Vac)
24 Vac (CT), 60 Hz 3 (0.06 amp, 4.0 watts at 115 Vac)
24 Vac (CT), 47— 63 Hz (0.03 amp, 4.0 watts at 230 Vac)
90 —132 Vac, 60 Hz 3 (1.65 amp, 165 watts at 115 Vac)
90 —132 Vac, 60 Hz 3 (1.25 amp, 111 watts at 115 Vac)
90 —132 Vac, 60 Hz 3 (2.4 amp, 215 watts at 115 Vac)
154 Btu/hr
154 Btu/hr
195 Btu/hr
December 1994
3000-A2-GA31-80

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents