[2] Reset mode for numbers of protection detections
[Purpose]
For clearing all the counts of protection detections.
(This mode resets the counts of protection detections.)
[How to enter/exit]
During Standby mode, simultaneously press and hold the [ALC/STANDARD SURR] and [STANDBY/ON] keys
for 10 seconds to enter this mode.
The display will return to the normal indication when no key operation is performed for 5 seconds.
B
[Basic operations]
Key Operation
(STANDBY state)
[ALC/STANDARD SURR]
+ [STANDBY/ON] keys
(press and hold the keys
for 10 seconds.)
[ENTER] key
C
(Counter Clear end)
(Normal display)
*1 "5 (-> normal)" denotes that the display will return to the normal indication when no key operation is performed
for 5 seconds.
*2 Indication when the BD function is selected
D
[Detailed explanations]
1. When the procedures for Reset mode for numbers of protection detections are completed, all the counters will be
reset to "000."
2. Prohibitions:
The protection detection counts cannot be cleared (reset to 000) with the MEMORY CLEAR process.
They can only be cleared when the procedures of Reset mode are completed.
E
F