5.2 ADAPTER ERROR MESSAGE

Functional Name
A
Adapter port overcurrent detection
Outline
When the BT adapter is inserted in Adapter port, turn off the power of the Adapter port forcibly when it detects an
overcurrent. And display ERROR state in FL.
Basic Operation
Front Key Sequence
Change
B
When the overcurrent is
detected
*1 Return the "ADP ERR" display to the normal display if you change it into other FUNCTION only in the
APAPTER PORT FUNCTION.
Also display "ADP ERR" if the ADAPTER PORT FUNCTION is ERROR state.
C
Explain Operation Detail
For detection method
• Confirm a detection port at intervals of 20 msec to 50 msec (*2), and judge it as an overcurrent when you detected an error
consecutively three times.
*2 It is assumed that it is fixed value of the 20 msec to 50 msec degree.
D

5.3 USB/iPod ERROR MESSAGE

Functional Name
E
iPod ERROR MESSAGE
Outline
Error message is displayed at abnormality time.
Basic Operation
Front Key Sequence Change
Over Current Error
F
44
1
2
Character Display
1 2
3 4 5 6 7 8
1 2
A
D P
E R R
*1
Check it after turning the power once
off then back on again, and it becomes
the normal operation if normal.
Time (sec)
2
3
Time (sec.)
The display continues until the
power is turned off.
FL Display
I / U
E R R
VSX-1022-K
3
4
Icon Display
LED Display
(FL)
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vsx-42Vsx-822-k

Table of Contents