5.9.3 Gas Table
Indications for the installation of the appropriate
injector and the adjustment of the air suction cap
Connection
Gas type
power
MODEL:
mbar
20
G20
G25
20
1 Group
G25
25
G30/31
28-30/37
50
G30/31
20
G20
20
G25
2 Groups
25
G25
G30/31
28-30/37
G30/31
50
G20
20
20
G25
3 Groups
25
G25
28-30/37
G30/31
50
G30/31
G20
20
G25
20
4 Groups
G25
25
28-30/37
G30/31
50
G30/31
TECHNICIANS manual
Injector inlet
Burner
minimum pressure
injector hole
mbar
1/100 mm
1.7
100
1.7
110
2.4
100
3.5
60
3.5
60
1.9
110
2.1
135
2.7
110
5.5
75
6.1
65
2.3
135
2.3
145
3.5
135
6.1
80
11.3
75
2.5
145
2.5
160
3.8
145
6.8
85
11.3
75
Aspiration air cap
Minimum
adjuetment
power Q min
mm
Kw
1
0.47
1
0.47
1
0.47
3
0.47
3
0.47
1
0.69
1
0.69
1
0.69
3
0.69
3
0.69
1
1.16
1
1.16
1
1.16
3
1.16
3
1.16
1
1.30
1
1.30
1
1.30
3
1.30
3
1.30
Maximum
Maximum
power Q n
consumption
Kw
m
3
/h
kg/h
1.67
0.177
-
1.67
0.177
-
1.55
0.164
-
1.40
-
0.110
1.80
-
0.142
2.03
0.215
-
2.52
0.267
-
1.88
0.199
2.20
-
0.174
2.10
-
0.167
3.06
0.323
-
2.91
0.308
-
2.85
0.302
-
2.51
-
0.199
2.84
-
0.225
3.55
0.376
-
3.55
0.376
-
3.30
0.349
-
2.85
-
0.225
2.85
-
0.225
27
68
of