Overview Of Operating Functions - Siemens Cerberus CS1140 Commissioning

Fire detection system. commissioning ’extinguishing’
Hide thumbs Also See for Cerberus CS1140:
Table of Contents

Advertisement

6

Overview of operating functions

Table 8: Functions 'Extinguishing TEST' and 'Extinguishing REVISION'
Function
Extinguishing REVI-
SION
Extinguishing TEST
Table 9: AlgoPilot list of functions 'SECTION'
List of functions SECTION 'extinguishing'
(based on standard text 'Switzerland')
BLOCKING autom. extinguishing
ENABLING autom. extinguishing
BLOCKING autom. & man. exting. release
ENABLING autom. & man. exting. release
set all DETECTOR zones ß OFF
set all DETECTOR zones ß ON
set all DETECTOR zones ß TEST
terminate TEST of all DETECTOR zones
set all DETECTOR zones ß INSTALL. TEST
terminate INSTALL. TEST of all DET. zones
set extinguishing control ß REVISION
terminate REVISION
set extinguishing control ß TEST
terminate TEST of exting. control
initiate TEST 'horn'
initiate TEST 'warning panel'
1)
only available from software V4.xx (EP4) onwards
2)
BLOCKING and ENABLING also possible 'alternating'
ß
BLOCKING via AlgoPilot and ENABLING via B3Q440 or vice versa
8
Fire & Security Products
Siemens Building Technologies Group
Purpose
Permits activation of sequence of
functions without horn, illuminated
warning panel and valves ('active'
status visible at maintenance LEDs
E3G080)
Permits the disconnection of the
path 'Extinguishing activated' via
AlgoPilot, e.g. for the testing of non-
Cerberus extinguishing systems etc.
Permits normal sequence, but with-
out activating the valves
1)
(2.1)
1)
(2.1)
(2.1)
(2.1)
(2.1)
(2.1)
(2.1)
(2.1)
(2.1)
(2.1)
(2.2)
(2.2)
(3)
(3)
(3)
(3)
Achieved
î via AlgoPilot
î via switch 'S1'
on E3G080
î via AlgoPilot
Notes
î also possible at extinguishing control panel
î also possible at extinguishing control panel
î also possible at extinguishing control panel
î also possible at extinguishing control panel
î concerns all detectors in the extinguishing SECTION
î concerns all detectors in the extinguishing SECTION
î blocks valves, horn, illuminated warning panel,
acknowledgement
Is also possible at the E3G080 by means of switch 'S1'
î blocks valves
î blocks valves
î briefly activates alarm horn (approx. 5sec)
î briefly activates illuminated warning panel
(approx. 5 sec)
Blocked
î Valves
î Illuminated warn-
ing panel
î Alarm horn
î Path 'Extinguish-
ing activated'
î Valves
2)
2)
2)
2)
e1456c
12.1997