9. Wind the end of the new wire with a ball as shown by steps 2 - 4 in the
illustration on the previous page.
10. Wind the end of the new wire with a ring as shown by steps 5 - 7 in the
illustration on the previous page.
11. Secure the screw of the wire tension bracket, with the wire tension spring
pulled as shown by step 7 in the illustration on the previous page.
12. Install the 1st scanner and adjust its position with the scanner positioning pins
(P/N A0069104) [A]. Then clamp the 1st scanner with the scanner positioning
pin as shown by step 8 in the illustration on the previous page.
13. Remove the positioning pins. After sliding the scanner to the left and right
several times, set the scanner positioning pins to check the clamp position and
wire tension bracket position again.