Table 5. Events for the physical disk component (continued)
Event
Event Type
ssd_endurance_warn
STATE_CHANGE
Recovery group events
The following table lists the events that are created for the Recovery group component.
Table 6. Events for the Recovery group component
Event
Event Type
gnr_rg_failed
STATE_CHANGE
gnr_rg_found
INFO_ADD_ENTITY
gnr_rg_ok
STATE_CHANGE
gnr_rg_vanished
INFO_DELETE_ENTITY
Severity
Message
WARNING
The
ssdEndurancePerc
entage of GNR pdisk
{0} is on a warning
value.
Severity
Message
ERROR
GNR recoverygroup
{0} is not active.
INFO
GNR recovery group
{0} was found.
INFO
GNR recoverygroup
{0} is ok.
INFO
GNR recovery group
{0} has vanished.
Description
Caus
User Action
e
The
The
SSDs have a finite lifetime
ssdEndurancePerc
ssdE
based on the number of
entage value is
ndur
drive writes per day. The
warning.
ance
ssd-endurance-percentage
Perc
values actually reported
enta
will be a number between 0
ge
and 255. This value
value
indicates the percentage of
of the
life that is used by the
pdisk
drive. The value 0 indicates
is
that full life remains, and
betw
100 indicates that the drive
een
is at or past its end of life.
95
The drive must be replaced
and
when the value exceeds
100.
100",
"state":"DEGRADED" }.
Description
Caus
User Action
e
The recovery group is
N/A
N/A
not active.
A GNR recovery group
N/A
N/A
listed in the IBM
Spectrum Scale
configuration was
detected.
The recovery group is
N/A
N/A
ok.
A GNR recovery group
A
Run the
listed in the IBM
GNR
mmlsrecoverygroup
Spectrum Scale
recov
command to verify that all
configuration was not
ery
expected GNR recovery
detected.
group
group exist.
,
listed
in the
IBM
Spect
rum
Scale
confi
gurati
on as
moun
ted
befor
e, is
not
found
. This