Table 4. Events for the Enclosure component (continued)
Event
power_no_power
power_supply_absent
power_supply_failed
power_supply_off
power_supply_ok
power_switched_off
sideplane_failed
sideplane_ok
temp_bus_failed
temp_high_critical
temp_high_warn
temp_low_critical
temp_low_warn
temp_sensor_failed
temp_sensor_ok
voltage_bus_failed
voltage_high_critical
Event Type
Severity
STATE_CHANGE
WARNIN
G
STATE_CHANGE
WARNIN
G
STATE_CHANGE
WARNIN
G
STATE_CHANGE
WARNIN
G
STATE_CHANGE
INFO
STATE_CHANGE
WARNIN
G
STATE_CHANGE
ERROR
STATE_CHANGE
INFO
STATE_CHANGE
WARNIN
G
STATE_CHANGE
WARNIN
G
STATE_CHANGE
WARNIN
G
STATE_CHANGE
WARNIN
G
STATE_CHANGE
WARNIN
G
STATE_CHANGE
WARNIN
G
STATE_CHANGE
INFO
STATE_CHANGE
WARNIN
G
STATE_CHANGE
WARNIN
G
Message
Description
Power supply {0}
Power supply has
has no power.
no input AC power.
The power supply
may be turned off
or disconnected
from the AC supply.
Power supply {0} is
The power supply
missing.
is missing
Power supply {0} is
The power supply
failed.
state is failed.
Power supply {0} is
The power supply
off.
is not providing
power.
Power supply {0} is
The power supply
ok.
state is ok.
Power supply {0} is
The requested on
switched off.
bit is off, indicating
that the power
supply has not
been manually
turned on or been
requested to turn
on by setting the
requested on bit.
sideplane {0}
The sideplane state
failed.
is failed.
sideplane {0} is ok.
The sideplane state
is ok.
Temperature
The temperature
sensor {0} I2C bus
sensor I2C bus has
is failed.
failed.
Temperature
The temperature
sensor {0}
has exceeded the
measured a high
actual high critical
temperature value.
threshold value for
at least one sensor.
Temperature
The temperature
sensor {0}
has exceeded the
measured a high
actual high warning
temperature value.
threshold value for
at least one sensor.
Temperature
The temperature
sensor {0}
has fallen below
measured a low
the actual low
temperature value.
critical threshold
value for at least
one sensor.
Temperature
The temperature
sensor {0}
has fallen below
measured a low
the actual low
temperature value.
warning threshold
value for at least
one sensor.
Temperature
The temperature
sensor {0} is failed.
sensor state is
failed.
Temperature
The temperature
sensor {0} is ok.
sensor state is ok.
Voltage sensor {0}
The voltage sensor
I2C bus is failed.
I2C bus has failed.
Voltage sensor {0}
The voltage has
measured a high
exceeded the
voltage value.
actual high critical
threshold value for
at least one sensor.
Cause
User Action
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Chapter 1. Events 7