Samsung DVM S Water AM080FXWANR Technical Data Book page 29

Vrf, r410a, 50/60hz, hp/hr premium energy efficiency type, premium compact type
Hide thumbs Also See for DVM S Water AM080FXWANR:
Table of Contents

Advertisement

6. Electrical Wiring Diagram
AM300KXWATT (30HP)
INV PBA1
Printed circuit board(Inverter PBA1)
INV PBA2
Printed circuit board(Inverter PBA2)
EMI PBA1
Printed circuit board(Noise Filter1)
EMI PBA2
Printed circuit board(Noise Filter2)
WATER HUB PCB Printed circuit board(Water related load control) SUCTTION1(10K) Temp. Sensor (Suction Temp.1_10Kohm)
MAIN PBA
Printed circuit board(main)
HUB PBA
Printed circuit board(hub)
COMM PBA
Printed circuit board(Communication)
COMP1
Motor (Compressor1)
COMP2
Motor (Compressor2)
FAN1
Motor (Outdoor Fan1)
FAN2
Motor (Outdoor Fan1)
EVI V/V 1
Solenoid Valve(EVI 1)
EVI V/V 2
Solenoid Valve(EVI 2)
Enhanced Vapor Injection
EVI EEV
Electrical Expansion Valve
NOTE
• This wiring diagram applies only to the water-cooled DVM S Water.
• Colors BLK: black, RED: red, BLU: blue, WHT: white, YEL: yellow, BRN: brown, SKY: skyblue
• When operating, don't short circuit the protection device (High Pressure switch)
• For connection wiring indoor-outdoor transmission F1-F2, outdoor-outdoor transmission OF1-OF2, refer to
the installation manual.
Protective earth (screw) ,
EEV1
Electrical Expansion Valve 1
EEV2
Electrical Expansion Valve 2
EVI-OUT(10K)
Temp. Sensor (EVI-out_10kohm)
EVI-IN(10K)
Temp. Sensor (EVI-in_10Kohm)
SUCTTION2(10K) Temp. Sensor (Suction Temp.2_10Kohm)
SNOW SENSOR
SNOW SENSOR
OIL-COMP1
Oil-Sensor (Compressor1)
OIL-COMP2
Oil-Sensor (Compressor2)
OUT(10K)
Temp. Sensor (Ambient Temp._10Kohm)
COND(10K)
Temp. Sensor (Cond Out Temp._10Kohm)
TOP1(200K)
Temp. Sensor (Compressor Top1_200Kohm)
TOP2(200K)
Temp. Sensor (Compressor Top2_200Kohm)
DIS1(200K)
Temp. Sensor (Discharge Temp.1_200Kohm)
DIS2(200K)
Temp. Sensor (Discharge Temp.2_200Kohm)
connector,
: The wire quantity
LIQUID(10K)
Temp. Sensor (Liquid Tube Temp._10Kohm)
HOTGAS1 V/V
Solenoid Valve (Hot Gas Bypass1)
EVI BYPASS V/V Solenoid Valve (EVI Bypass )
RETURN V/V
Solenoid Valve (Accumulator Oil Return)
4WAY V/V
Solenoid Valve (4Way Valve )
CCH1
Crank Case Heater(COMP1)
CCH2
Crank Case Heater(COMP2)
MAIN COOLING
Solenoid Valve (Main Cooling)
HOTGAS2 V/V
Solenoid Valve (Hot Gas Bypass2)
OD EEV V/V
Solenoid Valve (Outdoor EEV)
690V/T56A
FUSE(NOISE FILTER)
MODE CHANGE
Connector (Remote switching cool/heat selector)
EXT CON
Connector (Output EXT CON)
ERROR/COMP EXT Connector (Output ERROR/COMP EXT CON)
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents