Work Area Safety - Genie GS-2668DC Operator's Manual

Table of Contents

Advertisement

Operator's Manual

Work Area Safety

Electrocution Hazards
This machine is not electrically insulated and will
not provide protection from contact with or
proximity to electrical current.
Maintain safe distances from electrical power lines
and apparatus in accordance with applicable
governmental regulations and the following chart.
Line Voltage
0 to 50KV
50KV to 200KV
200KV to 350KV
350KV to 500KV
500KV to 750KV
750KV to 1000KV
Allow for platform movement, electrical line sway or
sag and beware of strong or gusty winds.
Keep away from the machine if it contacts
energized power lines. Personnel on the ground or
in the platform must not touch or operate the
machine until energized power lines are shut off.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for welding.
8
Required Clearance
3.05 m
4.60 m
6.10 m
7.62 m
10.67 m
13.72 m
GS-2668 DC • GS-3268 DC
Tip-over Hazards
Occupants, equipment and materials shall not
exceed the maximum platform capacity.
Machine without capacity indicator:
Maximum capacity
GS-2668 DC
GS-3268 DC
Machine with capacity indicator:
The maximum capacity varies with the height of the
platform.
Maximum capacity - GS-2668 DC
Maximum occupants
Height of Platform
7.9 m
6.4 m
4.8 m
3.2 m
1.7 m
Maximum capacity - GS-3268 DC
Maximum occupants
Indoor use
Outdoor use
Height of Platform
9.8 m
7.8 m
5.8 m
3.8 m
1.8 m
Fifth Edition · First Printing
567 kg
454 kg
Maximum Capacity
567 kg
771 kg
975 kg
771 kg
567 kg
Maximum Capacity
454 kg
686 kg
919 kg
686 kg
454 kg
Part No. 133557
4
4
2