Gemü Conexo; Product Label; Intended Use - GEM 125 Series Operating Instructions Manual

Limit switches
Table of Contents

Advertisement

Available languages

Available languages

5 Intended use

The GEMÜ 1252/1257 limit switches are both equipped with a
bistable reed contact and are signal generators for the min-
imum value. The contact is opened when the float, which is
equipped with a permanent magnet, passes upwards past the
limit switch (position B). The contact is closed when the float,
which is equipped with a permanent magnet, passes down-
wards past the limit switch (position A). The status of the
limit switch is retained until the float passes by again.
4.3 GEMÜ CONEXO
The interaction of valve components that are equipped with
RFID chips and an associated IT infrastructure actively in-
crease process reliability.
Thanks to serialization, every valve and every relevant valve
component such as the body, actuator or diaphragm, and
even automation components, can be clearly traced and read
using the CONEXO pen RFID reader. The CONEXO app, which
can be installed on mobile devices, not only facilitates and im-
proves the "installation qualification" process, but also makes
the maintenance process much more transparent and easier
to document. The app actively guides the maintenance techni-
cian through the maintenance schedule and directly provides
him with all the information assigned to the valve, such as
test reports, testing documentation and maintenance histor-
ies. The CONEXO portal acts as a central element, helping to
collect, manage and process all data.
For further information on GEMÜ CONEXO please visit:
www.gemu-group.com/conexo
In the corresponding design with CONEXO, this product has
an RFID chip (1) for electronic recognition. The position of the
RFID chip can be seen below.
Installing the RFID chip
RFID chip
GEMÜ 125x

4.4 Product label

Device version
Item number
The manufacturing month is coded under the traceability
number and can be requested from GEMÜ. The product was
manufactured in Germany.
5 Intended use
Improper use of the product
▶ Risk of severe injury or death.
▶ Manufacturer liability and guarantee will be void.
Only use the product in accordance with the operating
conditions specified in the contract documentation and in
this document.
The product with ordering option ATEX zone AT1 is intended
for use in potentially explosive areas of zones 1 and 2 with
gases, mists or vapours and zones 21 and 22 with combust-
ible dusts in accordance with EU Directive 2014/34/EU
(ATEX).
The products must:
Only be used for measuring the flowmeters of the
GEMÜ 800, GEMÜ 840 and GEMÜ 850 series.
Only be operated within the performance limits (see "",
page 25).
Not be modified from a constructional point of view.
The GEMÜ 1250 limit switches are equipped with a change-
over contact and can be used as minimum or maximum sig-
nal generators.
The GEMÜ 1251 and GEMÜ 1256 limit switches must only be
used as maximum-value signal generators.
The GEMÜ 1252 and GEMÜ 1257 limit switches must only be
used as minimum-value signal generators.
22 / 36
Design in accordance with order data
Device-specific data
Traceability number Serial number
WARNING
www.gemu-group.com

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

12501252125712511256

Table of Contents