Check monthly . . . . . . . . . . . . . . . .
Automatic air vents (if used)
1. See
Figure 4
2. Remove the cap from any
automatic air vent in the system
and check operation by
depressing valve
the tip of a screwdriver.
3. If the air vent valve appears to
be working freely and not
leaking, replace cap
all the way on.
4. Loosen cap A one turn to allow
vent to operate.
5. Have vent replaced if it does not
operate correctly.
Pilot burner flame
pilot flame (see
Proper
1. Blue flame.
2. Inner cone engulfing thermocouple or thermopile
(standing pilot) or pilot flame sensor (spark-ignited
pilot).
3. Thermocouple or thermopile, or pilot flame sensor
glowing cherry red.
Improper
1. Overfired — Large flame lifting or blowing past pilot
flame sensor.
2. Underfired — Small flame. Inner cone not engulfing
pilot flame sensor.
3. Lack of primary air — Yellow flame tip.
4. Incorrectly heated pilot flame sensor.
Figure 5 Pilot burner and flame, typical
Spark
electrode
Pilot flame
sensor (spark-
ignited pilots)
— or —
Thermocouple or thermopile
(standing pilots)
Part Number 550-110-592/1000
.
Figure 4
Automatic air
vent
slightly with
B
A
B
, twisting
A
):
Figure 5
pilot flame:
Main burner flame
main burner flame (see
Proper
1. Yellow-orange streaks may appear (caused by dust).
Improper
1. Overfired — Large flames.
2. Underfired — Small flames.
3. Lack of primary air — Yellow tipping on flames
(sooting will occur).
Figure 6 Main burner flame, typical
59204
Clean vent termination & air
intake screens
1. Remove all lint and debris from both the boiler air
intake screen and the flue discharge screen.
The boiler control module will sense blockage of
the air intake or flue and lockout if the blockage is
excessive. It will signal the failure by flashing the
appropriate indicator lights on the control board.
Inner
cone
2. If removing the debris does not allow the boiler to
operate correctly afterwards, contact your qualified
service technician to inspect the boiler and vent/
air systems.
Check condensate drain
system
1. Inspect condensate drain fittings and tubing. Verify
that condensate can flow freely to drain.
59318
Figure 6
main burner flame:
Transparent
blue flame
Inner flame
— CGs boilers only
):
59319