Conversion Standard Ps To Hot-Plug Ps - Fujitsu PRIMERGY TX150 S4 Options Manual

Hide thumbs Also See for PRIMERGY TX150 S4:
Table of Contents

Advertisement

10
Conversion standard PS to hot-
plug PS
V
CAUTION!
Observe the safety instructions in the
et seqq..
The standard power supply can be replaced by a hot-plug power supply. The
hot-plug power supply consists of up to two power supply modules. The upgrade
kit contains only one power supply module (for power supply redundancy the
second power supply module must be additionally ordered).
The upgrade kit for the hot-plug power supply consists of the following parts:
– PS cage with Power backplane (incl. power cables)
– locking rail
– one power supply unit
– dummy cover (if only one power supply module is installed, you have to
install the dummy cover in the second bay)
– several screws
– anti-tilt bracket
V
CAUTION!
After installing the hot-plug power supply the SDR (sensor data record)
data base must be updated. For this sequence you need a BIOS flash
diskette. This diskette contains the newest BIOS version, the BMC
firmware and the SDR data.
Ê Write a BIOS flash diskette by down loading the required data from
the software pool under
http://service.abg.fsc.net/support/softwareAssist.asp.
Ê Open the server as described in the
seqq..
Ê Disconnect all power cables from the system board and the drives (see the
cabling plans in the Appendix).
U41629-J-Z156-2-76
chapter "Safety notes" on page 13
chapter "Preparation" on page 19
Options Guide
et
49

Advertisement

Table of Contents
loading

Table of Contents