Specifications

Ratings
A in model number: 100 to 240 VAC, 50/60 Hz
Power supply voltage
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range
85% to 110% of rated supply voltage
Models with option selection of 800:5.2 VA max. at 100 to 240 VAC, and 3.1 VA max. at 24 VAC or 1.6 W max. at
Power consumption
24 VDC
All other models: 6.5 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or 2.3 W max. at 24 VDC
Temperature input
Sensor input
Analog input
Current input: 150 Ω max., Voltage input: 1 MΩ min.
Input impedance
(Use a 1:1 connection when connecting the ES2-HB/THB.)
Control method
ON/OFF control or 2-PID control (with auto-tuning)
SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA
Relay output
(reference value)
Control
Voltage output
output
Output voltage: 12 VDC ±20% (PNP), max. load current: 21 mA, with short-circuit protection circuit
(for driving
SSR)
Number of
2
outputs
Auxiliary
output
Output
SPST-NO relay outputs, 250 VAC, 3 A (resistive load)
specifications
Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference values)
Setting method
Digital setting using front panel keys
11-segment digital display, individual indicators, and bar display
Indication method
Character height: PV: 14.9 mm, SV: 7.1 mm
Multi SP
Up to eight set points (SP0 to SP7) can be saved and selected using the key operations, or serial communications.
Bank switching
None
Adaptive control, automatic filter adjustment, water-cooling output adjustment, indication data (power ON time
monitor, ambient temperature monitor, and control output ON/OFF count monitors), parameter masking, operation
after power ON, manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions,
Other functions
heater burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital filter,
robust tuning, PV input shift, run/stop, protection functions, extraction of square root, MV change rate limit, logic
operations, temperature status display, simple programming, moving average of input value, and display
brightness setting
Ambient operating
−10 to 55°C (with no condensation or icing),
For 3-year warranty: −10 to 50°C with standard mounting (with no condensation or icing)
temperature
Ambient operating
25% to 85%
humidity
−25 to 65°C (with no condensation or icing)
Storage temperature
Altitude
2,000 m max.
Recommended fuse
T2A, 250 VAC, time-lag, low-breaking capacity
Installation environment
Overvoltage category II, Pollution Degree 2 (EN/IEC/UL 61010-1)
Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
E5CD-800