QW3S3D Dehumidification Performance – Cooling Full Load
(Full Load Capacities Based Upon Rated Flow of 8 GPM of 15% Methanol/Mass at 1150 CFM Airflow)
Entering
Entering Air
Fluid Temp.
Temp. (°F)
(°F)
65°
70°
75°
80°
75° DB
62.5° WB
85°
90°
95°
100°
65°
70°
75°
80°
75° DB
64.1° WB
85°
90°
95°
100°
65°
70°
75°
80°
75° DB
65.5° WB
85°
90°
95°
100°
65°
70°
75°
80°
75° DB
66.7° WB
85°
90°
95°
100°
65°
70°
75°
80°
75° DB 68°
WB
85°
90°
95°
100°
65°
70°
75°
80°
80° DB
68.3° WB
85°
90°
95°
100°
TABLE 8A
Total
Sensible
Latent
Capacity
Capacity
Capacity
(MBtuH)
(MBtuH)
(MBtuH)
36.0
26.7
35.2
26.3
33.8
25.7
33.1
25.4
31.9
24.9
30.6
24.3
29.1
23.7
27.6
23.0
37.1
25.2
11.9
36.2
24.9
11.3
35.3
24.4
10.9
34.2
24.0
10.2
33.0
23.4
31.7
22.8
30.2
22.2
28.6
21.5
38.1
23.8
14.3
37.3
23.4
13.9
35.9
22.8
13.1
35.3
22.5
12.8
34.1
22.0
12.1
32.8
21.4
11.4
31.3
20.7
10.6
29.7
20.1
39.2
22.3
16.9
38.4
21.9
16.5
37.0
21.3
15.7
36.4
21.0
15.4
35.2
20.5
14.7
33.9
19.9
14.0
32.4
19.3
13.1
30.8
18.6
12.2
40.3
20.8
19.5
39.5
20.5
19.0
38.1
19.8
18.3
37.5
19.6
17.9
36.3
19.0
17.3
34.9
18.4
16.5
33.5
17.8
15.7
31.9
17.1
14.8
40.9
26.3
14.6
40.1
25.9
14.2
38.7
25.3
13.4
38.1
25.0
13.1
36.9
24.5
12.4
35.6
23.9
11.7
34.1
23.3
10.8
32.5
22.6
Pounds of
Water per
Sensible to
Hour
Total Ratio
Removal
9.3
8.8
74.17%
8.9
8.4
74.72%
8.1
7.6
76.04%
7.7
7.3
76.74%
7.0
6.6
78.06%
6.3
5.9
79.41%
5.4
5.1
81.44%
4.6
4.3
83.33%
11.2
67.92%
10.7
68.78%
10.3
69.12%
9.6
70.18%
9.6
9.1
70.91%
8.9
8.4
71.92%
8.0
7.5
73.51%
7.1
6.7
75.17%
13.5
62.47%
13.1
62.73%
12.4
63.51%
12.1
63.74%
11.4
64.52%
10.8
65.24%
10.0
66.13%
9.6
9.1
67.68%
15.9
56.89%
15.6
57.03%
14.8
57.57%
14.5
57.69%
13.9
58.24%
13.2
58.70%
12.4
59.57%
11.5
60.39%
18.4
51.61%
17.9
51.90%
17.3
51.97%
16.9
52.27%
16.3
52.34%
15.6
52.72%
14.8
53.13%
14.0
53.61%
13.8
64.30%
13.4
64.59%
12.6
65.37%
12.4
65.62%
11.7
66.40%
11.0
67.13%
10.2
68.33%
9.9
9.3
69.54%
Approximate Supply Air
DB
WB
54.4
52.1
54.5
52.3
54.8
52.4
55.2
52.9
55.6
53.2
56.2
53.6
57.0
54.1
57.8
54.6
55.6
53.5
55.7
53.7
56.0
54.0
56.3
54.3
56.8
54.7
57.4
55.0
58.1
55.5
59.0
56.0
56.7
54.9
56.9
55.1
57.1
55.2
57.5
55.7
58.0
56.1
58.6
56.4
59.3
56.9
60.1
57.4
57.9
56.3
58.0
56.5
58.3
56.6
58.7
57.1
59.2
57.5
59.8
57.8
60.5
58.3
61.3
58.8
59.1
57.7
59.2
57.9
59.5
58.0
59.9
58.5
60.3
58.9
60.9
59.2
61.6
59.7
62.5
60.2
60.1
58.0
60.3
58.2
60.5
58.3
60.9
58.8
61.4
59.1
62.0
59.5
62.7
60.0
63.5
60.4