Specifications and Reference Data
July 2017
A.2.4 HART 1—5 Vdc low power
(output code M)
Output
Three wire 1—5 Vdc output, user-selectable for linear or
square root output. Digital process variable superimposed
on voltage signal, available to any host conforming to the
HART Protocol.
Rosemount 2051
Digital communications based on HART Revision 5
protocol.
Rosemount 2051 with Selectable HART
The Rosemount 2051 with Selectable HART comes with
Selectable HART Revisions. Digital communications
based on HART Revision 5 (default) or Revision 7 (option
code HR7) protocol can be selected.
The HART Revision can be switched in the field using any
HART based configuration tool or the optional LOI.
LOI
The LOI utilizes a two button menu with internal and
external configuration buttons. Internal buttons are always
configured for LOI. External buttons can be configured for
either LOI, (option code M4), analog zero and span (option
code D4) or digital zero trim (option code DZ).
Power supply
External power supply required. standard transmitter
operates on 9 to 28 Vdc with no load.
Power consumption
3.0 mA, 27—84 mW
Output load
100 k or greater (meter input impedance)
Turn-on time
Performance within specifications less than 2.0 seconds
after power is applied to the transmitter.
97
A.2.5 Overpressure limits
Transmitters withstand the following limits without
damage:
Rosemount 2051C, 2051CF
Ranges 2—5: 3,626 psig (250 bar)
4,500 psig (310,3 bar) for option code P9
Range 1: 2,000 psig (137,9 bar)
Rosemount 2051T
Range 1: 750 psi (51,7 bar)
Range 2: 1,500 psi (103,4 bar)
Range 3: 1,600 psi (110,3 bar)
Range 4: 6,000 psi (413,7 bar)
Range 5: 15,000 psi (1034,2 bar)
Rosemount 2051L
Limit is flange rating or sensor rating, whichever is lower.
See table below:
Table A-3. Rosemount 2051L Flange Rating
Standard
Type
ANSI/ASME
Class 150
ANSI/ASME
Class 300
At 100 °F (38 °C), the rating decreases
with increasing temperature, per ANSI/ASME B16.5.
DIN
PN 10—40
DIN
PN 10/16
At 248 °F (120 °C), the rating decreases
with increasing temperature, per DIN 2401.
A.2.6 Static pressure limit
Rosemount 2051CD, 2051CF
Operates within specifications between static line
pressures of —14.2 psig (0,034 bar) and 3626 psig
(250 bar)
For Option Code P9, 4500 psig (310,3 bar)
Range 1: 0.5 psia to 2000 psig (34 mbar and 137,9 bar)
Reference Manual
00809-0100-4107, Rev CA
Carbon steel
Stainless
rating
steel rating
285 psig
275 psig
740 psig
720 psig
40 bar
40 bar
16 bar
16 bar