Fujitsu PRIMERGY RX600 S3 SAS Service Supplement Manual page 30

Hide thumbs Also See for PRIMERGY RX600 S3 SAS:
Table of Contents

Advertisement

Replacing the BMC board
Installing the BMC board
Figure 11: Installing the BMC board
Ê Position the BMC board as follows:
1. The pin (A) must be positioned over the hole provided in the system
board.
2. The contact strip of the BMC board must be positioned over the corre-
sponding strip on the system board (B).
Ê Carefully press the BMC board down so that it plugs into the system board.
I
After installing the new BMC board, you must update the firmware to
ensure correct operation.
Before you update the firmware, you must connect the jumper on the
bottom of the BMC board in such a way that overwriting is possible (see
page
45).