Page 1
ICM72 ML-52474, 52480 V U L C A N - H A R T C O M P A N Y , P . O . B O X 6 9 6 , L O U I S V I L L E , K Y 4 0 2 0 1 - 0 6 9 6 , FORM 30908 (11-94) INSTALLATION &...
IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED.
Installation, Operation, and Care of MODELS ICM24, ICM36, ICM48, ICM60 & ICM72 GAS INFRARED CHEESE MELTERS KEEP THIS MANUAL FOR FUTURE USE GENERAL The Vulcan Gas Infrared Cheese Melters use efficient gas heat and are available in 24, 36, 48, 60, or 72 inch widths.
ASSEMBLY — Legs (optional) If using legs, four legs are required on 24, 36, and 48" models; six legs are required on 60 and 72" models. Assemble legs to the bottom of the unit through threaded holes in the four corners of the unit; on 60 and 72"...
Page 5
GAS CONNECTION Caution: The pipe thread compound used when installing pipes must be a type that is resistant to the action of liquified petroleum or propane gases. Codes require that a manual gas valve be installed in the gas supply line ahead of the appliance. Make sure the pipes are clean and free of obstructions, dirt, and piping compound.
OPERATION WARNING: THE CHEESE MELTER AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING, AND SERVICING THE CHEESE MELTER. CONTROLS (Fig. 4) Burner Valve — Turn fully ON or OFF by rotating the control knob 1/4 turn. Pilot Adjustment Screw Burner Valve Fig.