Installing and Configuring the Edge Switch 2/12
Configure Switch Ports
Perform the procedure in this section to configure names and operating
characteristics for the switch ports.
To configure one or more ports:
1. Click Configure at the left side of the window. The Configure window opens
Figure 14: Block or unblock a port from the Configure window
48
with the Ports tab displayed
a. For each port to be configured, type a port name of 24 alphanumeric
characters or less in the associated Name field. The port name should
identify the device to which the port is attached.
b. Click the check box in the Blocked column to block or unblock a port
(default is unblocked). A check mark in the box indicates the port is
blocked. Blocking a port prevents the attached device from
communicating with the switch. A blocked port continuously transmits
the offline sequence (OLS).
(Figure
14).
Edge Switch 2/12 Installation Guide