3
Preparation
3.1
Preparing installation site
3.1.1
Installation site requirements of the
option box
▪ Mind the measurement guidelines:
Maximum distance between the option box and
control box EKCB07CAV3
▪ Mind the following spacing installation guidelines:
50
50
(mm)
▪ The option box is designed to be wall­mounted in indoor locations
only. Make sure the installation surface is a flat and vertical non­
combustible wall.
▪ The  option  box  is  designed  to  operate  in  ambient  temperatures
ranging from 5~35°C.
3.2
Preparing electrical wiring
3.2.1
Overview of electrical connections for
external and internal actuators
Item
Description
Power supply
1
Power supply for option
box
Interconnection cable
2
Interconnection cable
to control box
Optional equipment
3
Remote indoor sensor
Field­supplied components
4
Electric meter
5
Power consumption
digital inputs
6
Alarm output
7
Space cooling/heating
ON/OFF output
8
Changeover to external
heat source
(a)
Cable section 2.5 mm².
(b)
Minimum cable section 0.75 mm².
NOTICE
More  technical  specifications  of  the  different  connections
are indicated on the inside of the option box.
EK2CB07CAV3
Daikin Altherma low temperature monobloc option box
4P405546­1 – 2015.03
3 m
600
Wires
Maximum
running
current
(a)
2+GND
(b)
3 (max 3 m)
(b)
2
(b)
2 (per meter)
(b)
2 (per input
signal)
(b)
2
(b)
2
(b)
2
4

Installation

4.1
Opening the units
4.1.1
To open the option box
2
1
1
WARNING
The  screws  are  delivered  with  toothed  lock  washers.
ALWAYS use toothed lock washers, also when the screws
need  to  be  replaced.  Failure  to  follow  this  warning  may
result in electric shock.
INFORMATION
Do NOT remove the plugs from the front plate of the option
box.
4.2
Mounting the option box
4.2.1
To install the option box
1 Remove the front plate.
2 Hold the back plate against the wall and mark the fixation points
(2 on the top and 2 at the bottom).
NOTICE
Make sure that the marks (2 by 2) are completely level and
that their dimensions correspond to the figure below.
318 mm
3 Drill 4 holes and install 4 plugs (suitable for M5).
4 Put  the  screws  in  the  top  plugs  and  hang  the  box  on  the
screws.
5 Put the screws in the bottom plugs.
6 Fix the 4 screws firmly.
3 Preparation
Installation manual
3

Advertisement

loading