RSP Installation

Step 5
Wait at least 5 seconds to allow the fans to stop spinning. Then, pull the fan trayrout toward you and out of
the router.
Note
Note
Step 6
To remove the slave fan tray (N560-4-FAN-H), move the UNLOCK slider to the right to unlocl the slave fan
tray from the router.
Step 7
Grasp the slave fan tray handle with one hand and the outside of the chassis with the other hand.
Step 8
Pull the fan tray toward you no more than 1 inch to disengage it from the power receptacle on the midplane.
Step 9
Wait at least 5 seconds to allow the fans to stop spinning. Then, pull the fan tray toward you and out of the
router.
Note
This completes the steps for removing the fan tray from the chassis.
To install the new fan tray, follow the steps in

RSP Installation

This section describes the installation and removal of the RSP.

Installing an RSP Module

To install an RSP module in the router chassis, perform the following steps:
Procedure
Step 1
Slip on the ESD-preventive wrist strap that was included in the accessory kit.
Step 2
Choose a slot for the module. Make sure that there is enough clearance to accommodate any equipment that
will be connected to the ports on the module. If a blank module filler plate is installed in the slot in which you
plan to install the module, remove the plate by removing its 2 Phillips pan-head screws.
Step 3
Fully open both the ejector levers on the new module.
Caution
Step 4
Position the module in the slot. Make sure that you align the sides of the module with the guides on each side
of the slot, as shown in the figure below.
Cisco NCS 560-4 Router Hardware Installation Guide
82
As the fan tray slides out of the chassis, support the bottom of the fan tray with one hand and keep
your other hand on the fan tray handle.
The chassis must not be allowed to operate without functioning fans for more than 5 minutes.
As the fan tray slides out of the chassis, support the bottom of the fan tray with one hand and keep
your other hand on the fan tray handle.
To prevent ESD damage, handle modules by carrier edges only.