12.3. Adjustment Standard (Base Unit)

When connecting the simulator equipment for checking, please refer to below.

12.3.1. Bottom View

ANT_BT
Spectrum Analyzer
URX1
UART
PC
UTX1
JIG
GND1
ANT_1
Spectrum
Analyzer
Note:
(*1) refers to No.2 of Check Table for RF part (P.40)
(*2) refers to Power Supply Circuit/Reset Circuit (P.14)
All manuals and user guides at all-guides.com
A
55
KX-PRL260/KX-PRL262/KX-PRD260/KX-PRD262/KX-PRLA20
C403
RA611
Q702
Frequency Counter (*1)
Send command "SFR", then
the frequency output on this TP.
Oscilloscope (*2)
DC
5.5V