 2-C batteries power the wind/thermo-hygro sensor
 3-AAA Alkaline batteries for the wind speed station
 TX141Wv2 Wind Speed/Thermo-hygro sensor
 TX141TH-BCH Add-on channel 2 or channel 3 for additional temperature/humidity readings.
 The above 433MHz sensors will read to this wind speed station.
You can add up to two TX141TH-BCH* sensors for extra temp/humidity readings on channels 2 or
channel 3. (Wind Sensor uses channel 1).
1.
Remove the battery cover from all the sensors (leave battery covers off until all sensors are
received by the wind station).
2. Set the first additional sensor to Channel 2 and insert 2 AA batteries.
3. Set the second additional sensor to Channel 3 and insert 2 AA batteries.
4. Hold the TEMP button on the wind station for 5 seconds to search for sensors.
5. Press the TX button on each sensor.
6. When connection is established, the temperature & humidity for each of the selected channels
will appear.
7. Install the battery covers on each sensor.
8. Keep sensors and the wind station 5-10 feet apart for 15 minutes to establish a solid
connection.
9. After 15 minutes, place the remote sensors in appropriate shaded locations.
10. Press and release the -/CH button to view channels 1, 2 or 3 on the wind station when multiple
sensors are used.
*Additional sensors are sold separately & are available for purchase here:
www.lacrossetechnology.com/tx141th-bch-temperature-humidity-sensor

DASHES SHOWN FOR OUTDOOR TEMPERATURE/HUMIDITY/WIND SPEED

 Dashes means there is lost connection between the display and the outdoor sensor.
 Batteries are the most common problem.
 Distance/Resistance can cause loss of sensor signal. Avoid having more than one wall,
window, tree etc., between the display and the sensor. UV coated windows may actually
reflect the signal. Stucco walls will absorb the signal.
 It may be helpful to orient the weather 90 degrees towards the sensor for better reception.
 Sensors operate best when elevated at least 6 feet.
 Remove the batteries from the sensor for 2 minutes. Replace the batteries in the Thermohygro
sensor and after 5 minutes press and hold the TEMP button for 5 seconds. Wait 10 minutes. If
the unit does not receive a reading from all the sensors, please try the factory reset.

INACCURATE OUTDOOR TEMPERATURE/HUMIDITY