distribution where voltages do not exceed 240V AC.
All installations should confirm that the product is reliably grounded
according to the country's local electrical codes.
Building codes vary worldwide; therefore, NETGEAR strongly
Note:
recommends that you consult an electrical contractor to ensure
proper equipment grounding and power distribution for your specific
installation & country.

Cable Routing for LAN Systems

The 8800 series switches meet the requirements for LAN system equipment. LAN systems
are designed for intra-building installations; that is, cable runs between devices needs to be
in the same building as the connected units.
This equipment can be connected between buildings if any one of the following conditions is
true:
Cable runs between buildings are less than 140 feet long.
Cable runs between buildings are directly buried.
Cable runs between buildings are in an underground conduit, where a continuous metallic
cable shield or a continuous metallic conduit containing the cable is bonded to each
building grounding electrode system.
CAUTION:
Failure to follow these requirements for cable routing conditions may
expose the user to electrical shock and expose the unit to errors or
damage.
WARNING!
The intra-building ports of the equipment or sub-assembly are
suitable for connection to intrabuilding or unexposed wiring or
cabling only. The intra-building port(s) of the equipment or
sub-assembly MUST NOT be metallically connected to interfaces
that connect to the outside plant (OSP) or its wiring. These
interfaces are designed for use as intra-building interfaces only
110 |
Appendix A. Safety Information
8800 Series Chassis Switch Hardware Installation Guide