Vent Safety Switch; Electrical Connection - Majestic NVC36 Installation And Homeowners Operating Instructions

Decorative gas appliance
Table of Contents

Advertisement

NVC Series B-Vent

Vent Safety Switch

This fireplace incorporates the use of a Vent Safety
Shut-off Switch. The sensor and wiring are factory
installed and should not be removed or altered during
installation.
In the event of total flue blockage the system will detect
the increased heat buildup and will automatically shut
down the main burner assembly.
The sensor is located above the firebox behind the top
louvre assembly. It is accessible by removing the top
louvre assembly.
CAUTION: The firebox, Vent Safety Switch sensor
and surrounding panels become very hot during
normal operation. Allow time for the components to
cool before carrying out any service or inspection.
If the sensor is activated and shuts off the burner as-
sembly, the following procedure should be followed:
Observe that the pilot flame is still ON. If the pilot
flame has gone out the reason for the fireplace shut
down is not the vent safety switch.
Turn the pilot flame OFF and close all controls. Allow
the fireplace to cool.
Check the flue and venting components for blockage
or restrictions.
Remove the front louvre assembly.
Locate the sensor.
Reset the sensor by pressing the reset pin between
the two wire terminals. (Fig. 18)
CAUTION: The components may still be hot.
Light the fireplace and check for downdrafts.
Operate the fireplace in the normal manner. If the
burner assembly shuts down again after a period
of operation, DO NOT ATTEMPT TO RESET THE
SENSOR AGAIN. Turn off the fireplace and contact
your service technician.
Sensor
Wire Ter-
minal
Reset Pin
Fig. 18 Vent Safety Switch.
FP1160
14
Vent safety switch
11/2/01 djt
The sensor is wired in series between the wall mounted
ON/OFF switch and the Electronic Ignition Module (Fig.
19) or the thermopile and the gas valve (Fig. 20)
BLACK
Fig. 19 Vent Safety Switch wiring, EN/EP units.
Vent
Safety
Switch
Wire Terminal
Fig. 20 RN/RP units using a remote ON/OFF switch.
FP1160

Electrical Connection

PILOT
HONEYWELL S8600 B IGNITION MODULE
GND
24V
MV
MVPV
PV
24V
(BURNER)
GND
WHITE
BLACK
WHITE
NOVA SIT 822 VALVE
24 VAC HOT
120 VAC RTN
BLACK
WHITE
WHITE
BLACK
24 VAC RTN
120 VAC HOT
40VA
GREEN
TRANSFORMER
OnN/OFF
Switch
FP1161
Vent Safety Switch
Wiring
11/2/01 djt
WHITE
SPARK
SENSE
WHITE
BLACK
BLACK
BLACK
WHITE
ON-OFF
SWITCH
FP670
FP670
NOVA SIT 822 VALVE WIRING DGRM.
(w/ Honeywell S8600 B Ignition Module)
Thermopile
4/30/98
TH
Gas
TP
Valve
TH
TP
FP1161
20000194