Maintenance Of Motors; Cleaning Brass Trim; Electrical Diagram - Vermont Castings DEF33CE Installation Instructions & Homeowner's Manual

Vermont castings electric fireplace homeowner's installation and operating manual def33ce
Table of Contents

Advertisement

MAINTENANCE OF MOTORS

The motors used on the fan and the drum assembly are
prelubricated for extended bearing life and require no
further lubrication. However, periodic cleaning/vacuuming
of the fan/heater is recommended.
Make sure that the power is turned off
before proceeding.
Any electrical repairs or rewiring of this unit should be carried out by a licensed electrician in accordance with national and
local codes
If repairing or replacing any electrical component or wiring the original wire routing, colour coding and
securing locations must be followed.
10
HEATER ELEMENT
DRUM
MOTOR
2
11
12
3
POTENIOMETER
SPEED CONTROL
10003167
4
CFM Majectic Factory Wire Req'd
2. Motor Variable Speed (12V/DC)
3. potentiometer
4. Speed Control
5. Dimmer Switch Rotary
6. Thermostat
7. On / Off Switch
8. Light Socket
9. Light Bulb
10. Fan/Heater
11. Nylon Cable Tie
12. Grommet 7/8
ELECTRIC DIAGRAM
FAN
MOTOR
9
3 BLACK
4 WHITE
9
8
8
11
1 BLACK
2 WHITE
14 WHITE
6 WHITE
5 BLACK
13 BLACK
DIMMER
5
Clean the brass trim using a soft cloth, slightly dampened
with lemon oil and buff with a clean soft cloth. Do NOT use
brass polish or household cleaners as these products will
damage the brass trim. Lemon oil can be obtained at
supermarkets or hardware stores.
9 RED
10 BLACK
11 YELLOW
7 BLACK
8 WHITE
11
8
5 BLACK
6 WHITE
8 RED
THERMO STAT
6
8 WHITE
Wiring Colour Code:
WH =
White
BL =
Black
RE =
Red
- 8 -

CLEANING BRASS TRIM

12
7
11 YELLOW
11
14
13

Advertisement