Download Print this page

Hearth Extension - Majestic fireplaces 7TDVP12 Specification Sheet

Fireplace & venting specifications

Advertisement

CONTEMPORARY TERMINATIONS
813mm
165
127mm
mm
406mm
482mm
7TDVSKS
ELBOWS
OFFSET w/2-90°
Back to Back
330mm
13"
7
"
1/4
184mm
7TDVRT90
OFFSET w/2-45°
Back to Back
7
45°
188mm
7
"
3/8
188mm
7TDV45
9³⁄₄"
12¹³⁄₁₆"
7"
7TDVRVT
7TRVT
13³⁄₁₆"
9¹⁄₂"
7"
7TDVSKV
7 "
178mm
9
1/4
7
"
1/4
184mm
9
"
1/4
235mm
330mm
235mm
330mm
FP889
45°
"
3/8
45°
11"
7
"
3/8
188mm
FP890
FIREPLACE FACTS
PerfectView 39LDVT
FEATURES:
• 39 " PerfectView Direct Vent Gas Appliance
• 16,000 to 23,000 BTU/hr. input
• Patented Insta-Flame TM Ceramic Burner System with 4-piece
Split Oak Ceramic Fiber Log Set
• Tempered Glass Panel Assembly
• Adjustable Flame and Heat Output
• Wall Switch
• 18 " Flex Connector with Shutoff and EB1 electrical box installed
• Wall Firestop, Zero Clearance Sleeve (Rear vent models only)
• Rated as Fireplace Heater (AFUE)
• Uses 4 " /7 " Majestic (Direct Vent) Venting Components
BURNER SYSTEM:
• Capacity
– Natural:
– Propane:
• Fuel - Natural or Propane Gas
• Ignition System - Standing Pilot With Piezo Ignitor, A Low Voltage,
Self-Generating Power Pile System (mV)
– No Outside Electrical Power Needed OR
- Electronic ignition that requires 120 VAC Electrical hook up.
• Gas Supply Line - Consult Gas Code Book for Correct Sizing
Minimum Inlet Pressure
Maximum Inlet Pressure 14" w.c.
"
Manifold Pressure
335mm
MINIMUM FLOOR AREA:
90°
• 39" W X 16" D

HEARTH EXTENSION:

A Hearth Extension Is Recommended But Not Required
ACCESSORIES:
39LDVCR
FK12
FK24
IMTFK
Mantel Depth
2"
4"
6"
8"
10"
The Fireplace Facts Information Sheets are for
quick reference only and are subject to change with-
out notice. Actual fi replace instructions must abide
by specifi cations provided with each product.
REV. 10/07
23,000 BTU/HR Max.
16,100 BTU/HR Min.
22,500 BTU/HR Max.
16,875 BTU/HR Min.
Natural
5.5" w.c.
3.5" w.c.
- 39" LDV Ceramic Refractory
- Fan and Cord (160cfm) (for RN/RP only)
- Variable Speed Heat-Activated Fan Kit
- IMT Thermostat w/ Face Plate
Minimum Mantel Clearances
Clearance From Top
of Combustion Chamber Opening
To Bottom of Mantel
9"
11"
13"
15"
17"
Propane
11.0" w.c.
14.0" w.c.
10.0" w.c.

Advertisement

loading

This manual is also suitable for:

7tdvp12187tdvp247tdvp35647tdvp367tdvp487tdvp8 ... Show all