Technical Service; Specifications; Service Hints - Vanguard VGP30B Owner's Operation And Installation Manual

Vent-free propane gas heater
Table of Contents

Advertisement

TECHNICAL
SERVICE

SPECIFICATIONS

SERVICE
HINTS
100100
You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International's Technical Service Department at 1-800-323-
5190.
BTU (Variable)
Type Gas
Ignition
Pressure Regulator Setting
Inlet Gas Pressure (inches of water)
Maximum
Minimum
Dimensions, Inches (H x W x D)
Heater
Carton
Weight (pounds)
Heater
Shipping
When gas pressure is too low
• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat
• propane gas supply may be low
When gas quality is bad
• pilot will not stay lit
• burner will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local propane gas supplier.
VGP30B
VP2000BB
15,000/30,000
9,000/18,000
Propane Only
Propane Only
Piezo
Piezo
8" W.C.
8" W.C.
14"
14"
11"
11"
23.5 x 25.9 x 8.0
23.5 x 18.5 x 8.0
25.8 x 28.7 x 10.1
25.8 x 21.3 x 10.1
30
22
35
27
25

Advertisement