Operational Summary - Universal Security Instruments 3304 Instructions Manual

Smoke & fire alarm with silence feature and alarm origination feature
Table of Contents

Advertisement

CONDITION OF ALARM AUDIBLE & VISUAL SIGNALS BEFORE SOLUTION / RECOMMENDATION
HORN
Silent
Silent
Horn does not
sound when other
alarms are active
or horn does not
sound when
inter-connected
alarm's test
button is pressed
3 Beeps,
2 second pause,
Repeat
3 Beeps,
2 second pause,
Repeat
3 Beeps,
2 second pause,
Repeat
3 Beeps,
2 second pause,
Repeat
Silent
(alarmed
previously)
mode) or Blinks on
once approx every
Silent
mode) or Blinks on
once approx every
1 Chirp approx
every 40 seconds
3 Chirps approx
every 40 seconds
after LED flashes
THIS PRODUCT IS LISTED TO UL STANDARD FOR SAFETY,

OPERATIONAL SUMMARY

RED LED
Blinks On once
approx every
40-45 seconds
Blinks On once
approx every
40-45 seconds
Blinks On once
approx every
40-45 seconds
Blinks On
approx every
2 seconds
Off
Blinks On
approx every
2 seconds
Blinks On
approx every
2 seconds
Blinks On once
approx every
40-45 seconds
(normal operation
10 seconds
(silence mode)
Blinks On once
approx every
40-45 seconds
(normal operation
10 seconds
(silence mode)
Blinks On once
approx every
40-45 seconds
Blinks On once
approx every
40-45 seconds
UL217 BY UNDERWRITERS LABORATORIES, INC.
GREEN LED
AC Power is present. DC Power is present.
Stays On
Off
AC Power is not present and alarm is receiving DC
Power. Check the breaker or fuse box for power. If the
breaker or fuse box looks normal, call a licensed
electrician for assistance.
Press and hold the smoke alarm Test/Silence button
Stays On
for at least 5 seconds. If still no alarm, turn off AC Power
or Off
at the circuit breaker or fuse box and disconnect the
alarm from the mounting bracket and make sure the
connector plug is securely attached on units that did
not alarm. If still no alarm, have a licensed electrician
check to see if the yellow wire is connected to the neutral
wire.
Originating Smoke Alarm - If hazard is identified, please
Stays On
take all precautions if an alarm sounds by calling an
Emergency Service and getting out of the home.
Stays On
Non-originating Smoke Alarm - Another interconnected
smoke alarm has sensed smoke, causing all
interconnected units to sound.
Stays On
Nuisance Alarm - If there is no hazard present, verify
the alarm is mounted in the correct location (see User's
Manual, "AVOID THESE LOCATIONS" section). Reset
alarm as instructed below.
Stays On
Silence Feature is activated by pressing and releasing
the Test/Silence button on the initiating alarm while in
alarm condition. Silence mode will last for approx 8-12
minutes.
QUICK FIND
Stays On
system, it is difficult to determine which alarm initiated
the alarms to sound. The
allow you to immediately locate the originating alarm
(once the alarms have stopped sounding). To initiate
QUICK FIND
alarm; and, after releasing the button, the originating
alarm will continue to sound for approx 60 seconds.
Reset the originating alarm. NOTE: In a non-
interconnected installation, it is necessary to test each
alarm to determine the originating alarm.
Stays On
To Reset the Alarm - Hold the Test/Silence button for 10
seconds. This will clear alarm origination and clear
Silence mode. Reset after each smoke alarm event.
Stays On
Low Battery - Check to make sure the battery activation
pull tab has been completely removed, battery polarity
is correct and the battery terminals are making contact
with the smoke alarm contacts in the battery drawer. If
chirp continues, replace the 9V battery (see User's
Manual for recommended battery types).
Stays On
Trouble/Service Alarm. Replace Alarm.
Page 9
SOLUTION / RECOMMENDATION
®
Alarm Origination - In an interconnected
QUICK FIND
®
, press the Test/Silence button on any
®
feature will

Advertisement

Table of Contents
loading

This manual is also suitable for:

38953304l3895l

Table of Contents