Operational Summary - Universal Security Instruments Sensing Plus AMI1061S Instructions Manual

Multi-criteria single/multiple station smoke alarm
Table of Contents

Advertisement

CONDITION
RECOMMENDATION
New - Out of Package
AC Power is present
DC Power is present
AC Power is not present
DC Power is present
Test/Silence
button has been
pressed
One or more alarms
not responding to
interconnected alarm
Originating Smoke Alarm
Non-originating
smoke alarm. Another
interconneced smoke
alarm has sensed smoke,
causing all interconnected
units to alarm.
Nuisance Alarm
One alarm has sensed
smoke and is
now silent.
Alarm needs to be reset
due to varying
conditions/previous
alarms
Low Battery
Product End-of-Service
Life signal
THIS PRODUCT CONFORMS TO UL 217 8TH EDITION STANDARD FOR SAFETY
Quick Reference Guide Model AMI1061S
ALARM AUDIBLE & VISUAL SIGNALS
RED LED
HORN
Silent
Silent
Blinks On once
approx every
2 minutes
Silent
Blinks On once
approx every
2 minutes
3 beeps,
Blinks On
6 second
pause
with horn
Horn does not
Blinks On once
sound when other
approx every
alarms are active
2 minutes
or horn does
not sound when
interconnected
alarms test button
is pressed
3 Beeps,
Blinks On
2 second pause,
Repeat
with horn
3 Beeps,
Blinks on approx.
2 second pause,
every 2 minutes
Repeat
3 Beeps,
Blinks On in
2 second pause,
sync with horn
Repeat
Silent
Blinks On once
approx every
2 minutes
(normal
operation mode)
or Blinks On
once approx
every 10 seconds
(silence mode)
Silent
Blinks On once
approx every
2 minutes
(normal operation
or Blinks On
once approx
every 10 seconds
(silence mode)
1 Chirps approx
Blinks On once
every 60 seconds
approx every 2
minutes
2 Chirps approx
Blinks On once
approx every 2
every 60 seconds
minutes
GREEN LED
Off
Off
Stays On
Off
Stays On
in sync
Stays On
Stays On
in sync
Stays On
Stays On
Stays On
Stays On
mode)
Stays On
Stays On
Page 10
RECOMMENDATION
To activate the alarm, remove the pull tab. The
alarm will sound one long beep to confirm it is
powered up. Press the Test/Silence/Reset button.
Test the alarm following installation and weekly
thereafter. The built-in test switch accurately tests
the alarm operation as required by ANSI/UL217
Standards for Safety Standards for Safety. If, at any
time, you test the alarm and it does not perform as
described, replace it immediately.
Alarm is operating properly.
Check the breaker or fuse box for power. If the
breaker or fuse box looks normal, call a licensed
electrician for assistance.
The alarm is operating properly.
Press and hold the smoke alarm Test/Silence
button for at least 5 seconds. If still no alarm,
turn off AC Power at the circuit breaker or
fuse box and disconnect the alarm from the
mounting bracket and make sure the connector
plug is securely attached on units that did not
alarm. If still no alarm, have licensed electrician
make sure the yellow wire is not mistakenly or
accidentally connected to the white (neutral)
wire. NOTE: In an interconnected system
containing a CO alarm, the CO alarm will
not respond to the smoke alarm signal and
the smoke alarm will not respond to the CO
alarm signal.
If alarm sounds and hazard is identified,
please take all precautions by getting out of
the home immediately and then calling an
Emergency Service.
If alarm sounds and hazard is identified,
please take all precautions by getting out of
the home immediately and then calling an
Emergency Service.
If there is no hazard present and the unit is
still sounding, activate the silence feature by
pressing and releasing the Test/Silence button
on the initiating alarm. Silence mode will last for
approx 10 minutes, with the red LED blinking
once approx every 10 seconds. Verify the
alarm is mounted in the correct location (see
User's Manual, "AVOID THESE LOCATIONS"
section). Reset alarm as instructed below.
QUICK FIND
Alarm Origination - In an
®
interconnected system, it is difficult to determine
which alarm initiated the alarms to sound. The
QUICK FIND
feature will immediately allow
®
you to locate the originating alarm (once the
alarms have stopped sounding). To initiate
QUICK FIND
, press and hold the test/silence
®
button on any alarm until the test sequence on
this alarm begins. Release the test button. The
specific horn pattern/sequence is designated
by the alarm type. Once this test sequence
ends, the originating alarm continues to sound
for approximately 60 seconds. In a non-
interconnected installation, it is necessary to
test each alarm to determine the originating
alarm. Reset alarm as instructed below.
To Reset the Alarm, press the Test/Silence
button for approx 10 seconds. This will clear
Alarm Origination. Reset after each smoke
alarm event.
Deactivate alarm (see User's Manual "ALARM
DEACTIVATION" section. Replace alarm
immediately.
Deactivate alarm (see User's Manual "ALARM
DEACTIVATION" section. Replace alarm
immediately.

Advertisement

Table of Contents
loading

Table of Contents