Trouble Shooter's Guide - Brinkmann SFC1520 Series Operating Instructions Manual

Cutter pumps
Table of Contents

Advertisement

BRINKMANN-Cutter pumps SFC1520...3000

9 Trouble shooter's guide

Fault
Motor does not start, no motor
noise
Motor does not start, humming
noise
Overload trips
Power consumption is too high
Motor overheats
Pump does not pump
The pump pumps no chips
Insufficient flow and pressure
Incorrect flow or pressure
Running noise/Vibration
BE3185
Cause
At least two of the power supply
leads have failed
Overload has tripped
One of the supply leads has failed
Impeller faulty
Motor bearing faulty
Pump locked up mechanically
High on/of cycling frequency
Wrong direction of rotation of im-
peller
Lime or other deposits
mechanical friction
High on/off cycling frequency
Wrong power supply (voltage or
cycles)
Insufficient cooling
liquid level too low
Pump mechanism faulty
Pipe blocked
Chip breaker worn or damage
Wrong direction of rotation of im-
peller
Pump mechanism silted up
Worn pump mechanism
Wrong power supply (voltage or
cycles)
Foreign objects in pump end
Impeller damaged
Bearing/Bushing broken
11/2019
Edition
Remedy
Check fuses, terminals and supply
leads.
Inspect overload
See above
Replace impeller
Replace bearing
Inspect pump hydraulics
Check application
See above
Clean pump mechanism
repair pump
See above
Power supply must correspond
with name plate rating
Check air flow at motor fan
Fill up liquid
replace pump mechanism
Clean pipe
Replace the chip breaker
Change over two power supply
leads
Clean pump mechanism
Replace pump mechanism
Power supply must correspond
with name plate rating
Remove foreign objects
Replace impeller
Replace bearing/bushing
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents