Brinkmann Vortex Pumps of the Series SFT1554-C Contents Indication to the manual ........2 8 Servicing and Maintenance ....... 6 Description of the Product ......2-3 9 Troubleshooting Guide ........7 Safety instructions ..........4 10 Spare Parts ............. 8-9 Transportation and Storage .......
Page 3
Technical data Max. del. Max. del. Height Depth of Weight Power pressure volume immersion (4-Pole) spec. weight 1 Type l/min Inches mm Inches SFT1554S 360-C 900 22.6 14.29 4.55 490-C 19.41 1) Dimensions in accordance with page 5 The motor is surface-cooled and compliant with DIN IEC 34 and EN 60034 (protection degree IP 55).
3 Safety instructions Safety instructions relevant for operation When operating the pump, the safety instructions If hot or cold machine components involve haz- contained in this manual, the relevant national acci- ards, they must be guarded against accidental dent prevention regulations and any other service and contact.
5 Installation and Connection Electric wiring Mechanical installation During any assembly or disassembly process the pumps must be secured against tipping trough ropes for example at all times. Pumps must be mounted securely. Piping, tank and pumps All service work must be carried out by qualified must be mounted without any tension.
6 Start-up / Shut-down ATTENTION Start-up The SFT pump should be operated in continual ATTENTION operation mode, not pulsed mode! Switch off at the mains. Pulsed mode causes increased wear due to the After connection the electrical wires, close the termi- return flow of chips and additional load on the nal box.
9 Troubleshooting Guide Fault Cause Remedy Motor does not start, no motor At least two of the power supply Check fuses, terminals and supply noise leads have failed leads . Overload has tripped Inspect overload Motor does not start, humming noise One of the supply leads has failed See above Impeller faulty...
10 Spare Parts 10.1 Spare Part List for the Immersion umps of the Series SFT1554-C Item Description Stator with terminal board Motor flange End shield Terminal box Fan cover Ball bearing DIN 625 10 Ball bearing DIN 625 11 Gasket...
10.2 Indications to the spare part order 11.2 Assembling the insert shaft and motor shaft Spare parts are available from the supplier. ATTENTION Standard commercially available parts are to be purchased in accordance with the model type. Clean the contact surfaces of the insert shaft (2) The ordering of spare parts should contain the follow- (inside) and the motor shaft (3).
Brinkmann Pumps, Inc. warrants that the product contained herein conforms to the descrip- tion in Brinkmann's catalog and that if this product shall fail to conform to the description thereof or to any express or implied warranty, Brinkmann shall, upon written notice of such nonconformity within one year of the date of its shipment from BRINKMANN'S plant, repair or replace such non-conforming material at the original point of delivery.