Replacement routines
4.4

Replacing the LocalView module

I
The LocalView module is used exclusively in the rack model.
It is delivered in a module frame which engages in the bay. The engage-
ment lock must therefore be pressed for removal of the module frame.
Requirements
– The server has been switched off
– The power cables have been uplugged
– Rack model only: The server has been pulled out
– The housing cover has been removed
– The CD/DVD drive has been removed (see Options Guide)
Removing the LocalView module
Ê For easier access, unplug the cables to the control panel and the control
panel board from the SCSI backplane.
B
Figure 10: Removing the LocalView module
Ê Remove the connection cable (4-pin I
LocalView module from the SCSI backplane (A) and the chassis ID module
(see
page
33).
LocalView module
2
Service Supplement TX600 S3
Replacing the LocalView module
A
C bus cable) which leads to the
27