V430-Af2R - Omron MicroHAWK V/F3 F Series Installation Manual

Optics and lighting accessory kit
Table of Contents

Advertisement

MicroHAWK V/F430-F with Ring Light Polarizer Installation
Polarizer Kit Hardware, MicroHAWK V/F430-F with Ring Light
Qty
Description
1
Window Assembly (included)
Window Gasket (included)
1
2
#2-56 X 3/8" Phillips Flat Head Screw (included)
#4-40 X 1/4" Phillips Pan Head Screw w/ Lock
4
Washers (included)
1
Phillips Torque Wrench (not included)
Window Removal, MicroHAWK V/F430-F with Ring Light
Step 1: Disconnect power from the camera.
Step 2: Unscrew the four #4-40 pan head screws that secure the window.
Step 3: Remove the gasket from around the window frame.
Step 4: Remove the two #2-56 flat head screws. Remove and dispose of the diffuser.
Note: Do not touch the electronics or lens, as this may cause damage.
Kit Part Number
V430-AF2R (Polarizer)
N/A