Checklist Before Installation

Intake
To admit fresh combustion air from outdoors, provide an
opening in the room of at least one square inch per 4,000
BTU/hr. If there are corrosive fumes or materials in the air,
then supply the burner with clean air from an
uncontaminated area.
Exhaust
Do not allow exhaust to accumulate in the work area.
Provide some positive means for exhausting them from
the furnace and the building.
Access
Make sure that you install the system in such a way that
the burners and components are easily accessible for
inspection and maintenance.
Table 3.1 Dimension A Inches (mm) for TFB030
Fuel
Natural Gas
Propane
Butane
Eclipse TFB, V2, Installation Guide 310, 11/14/2014
Environment
Make sure the local environment matches the original
operating specifications. Check the following items:

Prepare the Burner

Burners
adjustments may be necessary for your particular
application. If re-calibration is required, follow the
instructions that follow:
Step 1: Adjust the Nozzle
General Information
The distance between the end of the air tube and the end
of the nozzle, dimension A, is very important. If dimension
A is not correct, burners may not operate properly. Based
on the information provided in Table 3.1, Table 3.2, or
Table 3.3, verify that dimension A is correct for your
operating conditions. If adjustment is necessary, follow
the instructions on page 8, "Adjust the Nozzle".
Find Dimension A
Dimension A is different for each fuel type, tube diameter
and burner size.
50k-100k
101k-150k
0.251 (6.4)
0.251 (6.4)
0.125 (3.2)
0.125 (3.2)
0.125 (3.2)
0.125 (3.2)
• Voltage, frequency and stability of the electrical
power
• Type and supply pressure of the fuel
• Availability of enough fresh, clean combustion air
• Humidity, altitude and temperature of air
• Presence of damaging corrosive gases in the air
are
calibrated
Figure 3.1. Nozzle Adjustment
• For TFB030, use Table 3.1
• For TFB075, use Table 3.2
• For TFB200, use Table 3.3
151k-200k
201k-300k
0.374 (9.5)
0.374 (9.5)
0.251 (6.4)
0.251 (6.4)
0.125 (3.2)
0.125 (3.2)
at
the
factory.
However,
Dimension A
7