Epson
Function
Absoulte Horizontal
Position
Relative Horizontal
Position
Set Print Position
80
Commands
(ASCII, Decimal, Hexadecimal)
ASCII: ESC $ n
n
1
2
Dec: 27 36 n
n
1
2
Hex: 1B 24 n
n
1
2
ASCII: ESC \ n
n
1
2
Dec: 27 92 n
n
1
2
Hex: 1B 5C n
n
1
2
ASCII: ESC DLE @ P
A
n
1
P
P
3
4
Dec: 27 16 64 [data]
Hex: 1B 10 40 [data]
Notes
Move to new horizontal position.
Amount of movement from left margin
is calculated as follows:
[n
+ (n
x 256)] x (basic unit in inches),
1
2
where the basic unit is set by ESC (U, set
unit command. The default of the basic
unit is 1/60 inch.
n
=0 to 255
1
n
=0 to 255
2
n
=n
=0: left margin
1
2
Max. value: for 1/60 inch basic unit,
n
=48 n
=3(13.6" shift)
1
2
Space moved using this command will
not be underlined. DEL command will
not delete the skipped amount.
Move to new horizontal position, rela-
tive to present position. Amount of
movement is calculated as follows:
(n
+ [n
x256] x (basic unit in inches),
1
2
where the basic unit is set by ESC (U, set
unit command. The default of the basic
unit with LQ is 1/180 inch, and with
UTL it is 1/120 inch.
n
=0 to 255
1
n
=0 to 255
2
n
=n
=0: no movement
1
2
+ moves to right; - moves to left
A
P
P
OKI unique command. Sets next hori-
2
1
2
zontal position of printhead.
Pn= number of parameter bytes to fol-
low, range 0 to 255
A
= specifies whether motion is abso-
1
lute or relative: even-absolute from
left margin; odd=relative from present
position
A
= specifies direction of relative
2
movement: even= toward right margin
(forward); odd= toward left margin (re-
verse)
0 P
, P
, P
1
2
3
number of units to move (size of unit
depends on character pitch)
Appendix C: Priner Commands
, P
9 representing
4

Hide quick links: