Oki 390/391 Handbook page 112

Microline 390/391 turbo printer handbook
Table of Contents

Advertisement

IBM
Function
Proportional Spacing
Set 10 Cpi Pitch
Set 12 Cpi Pitch
Set 15 Cpi Pitch
Set Compressed Pitch
ML390/391 Turbo Printer Handbook
Commands
(ASCII, Decimal, Hexadecimal)
ASCII: ESC P n
Dec: 27 80 n
Hex: 1B 50 n
ASCII: DC2
Dec: 18
Hex: 12
ASCII: ESC :
Dec: 27 58
Hex: 1B 3A
ASCII: ESC g
Dec: 27 103
Hex: 1B 67
ASCII: SI
Dec: 15
hex: 0F
Notes
P
=3: specifies the number of parame-
n0
ters (in bytes) to follow
Character Pitch
m=0: unchanged
m=1: Proportional
m>5: m/360 inch
Point size=(n
+ [n
x 256]) x 0.5 point
1
2
Point size can be selected between a
minimum of 8 point to a maximum of
64 point.
Engages/ cancels proportional spacing
n=0 to 255:
n is odd number: start proportional
spacing
n is even number: stop proportional
spacing
When printer is in utility mode, this
command will switch it to LQ propor-
tional until it is canceled.
This is standard pica typewriter size.
Changes to 12 cpi except if Menu item
"SI Select (12 CPI)" is set to "20", then
ESC: will change 17.1 cpi to 20 cpi and
will not change 20 cpi.
OKI unique command. Sets 15 cpi.
Condenses cpi as follows (depending on
MENU setting for SI Select Pitch):
10 cpi: 15 cpi for SI=10; 17.1 cpi for SI=12
12 cpi: 12 cpi for SI=10; 20 cpi for SI=12
15 cpi: 15 cpi for SI=10; 17.1 cpi for SI=12
17.1 cpi: 15 cpi for SI=10; 17.1 cpi for
SI=12
20 cpi: 15 cpi for SI=10;17.1 cpi or 20 cpi
for SI=12
105

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Microline 390Microline 391 turboMicroline 390 turbo

Table of Contents