7.4
Technical data
Beverage dispensing,
continuous
Temperature classification
Supply voltage
Max. power consumption
Max. current consumption
Heat output **
Air volume flow
Power, compressor *
Ice bank weight
Ice build-up capacity
Water bath capacity
Dimensions
Height
Width
Depth
Transport weight
*
at -10 °C evaporation temperature
**
at 32 °C ambient in the working area
We reserve the right to make technical changes.
SAT systems
8.1
Responsibility for the system design
The design of the refrigeration circuit, consisting of the evaporator present in the unit and the system
components required on site for completion of the refrigeration circuit falls within the technical and legal
area of responsibility of the system planner.
Warning
Any warranty on the part of Cornelius will be rendered null and void in the event of
improper design and/or installation.
8.2
System requirements
The unit demonstrates a maximum refrigeration capacity in line with the table below.
2500
700
Triton
350
150
5
4
Dimension
3
2
70
CR
50
This refrigeration capacity must be taken into account for the design of the system.
Cornelius Deutschland GmbH
Document no: TD1015100
Version A, 28.10.2019, Index 0
Energize 4
31.5 l/h
N (32 °C)
220 V / 60 Hz
2000 W
9.8 A
1850 W
-
870 W
30 kg
2400 kcal
80 l
660 mm
950 mm
515 mm
110 kg
Maximum value
Customer value MIN
pull down
kcal/h
W
kcal/h
2400.0
2791.2
1300.0
1300.0
1511.9
900.0
1050.0
1221.2
600.0
580.0
674.5
400.0
2400.0
2791.2
1350.0
1500.0
1744.5
750.0
1170.0
1360.7
850.0
550.0
639.7
450.0
670.0
779.2
400.0
400.0
465.2
250.0
Energize 5 dual
48.5 l/h
N (32 °C)
220 V / 60 Hz
2200 W
10.6 A
2500 W
-
1420 W
50 kg
4000 kcal
155 l
810 mm
1080 mm
690 mm
130 kg
W
1511.9
1046.7
697.8
465.2
1570.1
872.3
988.6
523.4
465.2
290.8