Sony BRS-200 Operational Manual page 70

Hide thumbs Also See for BRS-200:
Table of Contents

Advertisement

Switcher Mode Menu
Adjustment
Indication/
control
Setting item
--
SW MODE
SNAP:
WIPE:
PIP:
F1
MV TYPE
F2
XPT HOLD
DSK HOLD
PIP HOLD
F3
WIPE
PATTERN
DIRECT
F4
ME AUTO
DSK AUTO
PIP AUTO
MEM Menu
Setting menu
Setting item
400 FREEZE..
410 SIGNAL
DIST
FREEZE
MODE..
420 FM 1
FM 2
FOLDER
NV MEM..
430 LOAD
STORE
TIME..
440 MM/DD/YY
<=>
HH:MM:SS
<=>
(Switcher mode indication)
0 to 99 (snapshot number
indication)
0 to 9 (direct wipe number
indication)
0 to 9 (direct PIP number
indication)
1, 4, 10, 16
Off, On
Off, On
Off, On
(Wipe pattern figure)
SS, Wipe, PIP
0 to 999 (30)
0 to 999 (30)
0 to 999 (30)
IN 1, IN 2, IN 3, IN 4, IN 5, IN 6,
IN 7, IN 8, IN 9, FM 1, FM 2,
MAT1, MAT2, CLBR, PGM, PVW
FM 1, FM 2
Exec
Frame, Field1, Field2
Frame, Field1, Field2
Separate, AutoSwap
NOP,
FM 1,
NOP,
FM 1,
01/01'09
00:00:00
Set
Description
The number of mode selected under DIRECT above the F3 control
is displayed.
Selects the type of multi-viewer.
Selecting On when the preset value stored in a snapshot number
was recalled disables switching among XPT (cross-point button),
DSK and PIP select buttons.
Press the F2 control to select XPT HOLD, DSK HOLD or PIP HOLD
then turn the F2 control to select On or Off.
Press the F3 control to select WIPE PATTERN or DIRECT.
When WIPE PATTERN is selected, turn the F3 control to select the
desired wipe pattern.
When DIRECT is selected, select direct select mode from among
SS (snapshot), Wipe and PIP.
Press the F4 control to select ME AUTO, DSK AUTO or PIP AUTO
then turn the F4 control to set the transition time.
Description
Allows you to register a still image in frame
memory 1 or 2.
Turn the F1 control to select a signal then turn the
F2 control to specify FM1 or FM2. Press the F3
control to register the image.
Sets up the signal imported to FM 1 or FM 2 as a
still image.
Setting FOLDER to AutoSwap automatically
swaps between the data in FM 1 and FM 2 after
importing the data.
Stores still image data in nonvolatile memory and
FM 2,
Both
recalls them.
FM 2,
Both
LOAD: Writes the data in nonvolatile memory to
FM 1 or FM 2. (When the switcher is on, data
are written automatically.)
STORE: Stores still image data of FM 1 or FM 2 in
internal nonvolatile memory. It takes about 3
minutes to store one frame memory.
Enter the date and time when the data are stored
in a computer.
Press the F1 control to highlight the date then turn
the F1 control to change the date. To move the
highlighted position, turn the F2 control.
In the same manner as above, change the time
using the F3 and F4 controls. To register the
settings, press the F4 control.
Note
The switcher does not have a built-in clock. The
entered date and time will not be updated.
70
Technical Appendix

Advertisement

Table of Contents
loading

Table of Contents