Operating Time Limiter - CDA HN6732FR Installation, Use And Maintenance Manual

Table of Contents

Advertisement

keeping the internal components as cool as possible.
If a pot is removed from the cooking zone whilst the booster function
is in use, the ten minute countdown continues.

Operating time limiter

In addition to the booster deactivation timer, each zone has an
operating time limiter to increase overall efficiency and to prevent
the hob from being left on indefinitely. If a zone's heat setting is
not changed for a specific duration then the associated zone is
automatically switched off and residual heat indicator activated.
Zones can still be used as normal in accordance with the operating
instructions. The operating time limiter is set according to the last
selected heat setting. The maximum operating times for each setting
can be found below.
Operating time limiter durations
Zone Heat Setting
Maximum
Operating Time
(hours)
3
1
2
8
8
8
5
8
4
5
6
7
5
5
1.5
1.5
1.5
9
11
12
10
P
1.5
1.5
1.5
1.5
0.16
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents