Initialization Of 8, A, B, C, D, E, F; Loading Of Flash Memory Program; Preparation; Loader Writing Permission Mode Setting - Sony DCR-HC65 Adjusting Manual

Hide thumbs Also See for DCR-HC65:
Table of Contents

Advertisement

DCR-HC65
1-2.

INITIALIZATION OF 8, A, B, C, D, E, F, 14, 18,

19, 1A, 1B, 1C, 1E, 1F PAGE DATA
Note: When reading or writing the 14, 18, 19, 1A, 1B, 1C, 1E or 1F page
data, select page: 0, address: 10, and set data: 01, then select 4, 8, 9,
A, B, C, E or F page. The 14, 18, 19, 1A, 1B, 1C, 1E or 1F page can
be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
"00".
1-2-1.

LOADING OF FLASH MEMORY PROGRAM

Read the program for the HI/DS controller (IC8401) from the
Memory Stick Duo, and write it to the flash memory (IC8503) of
the HI/DS controller.
Note: The data of page: 0, address: 10 must be "00".

1. Preparation

1)
Write the VERMEER. BIN file (program file for the HI/DS
controller) to a Memory Stick Duo using a personal computer.
Note: Contact our service headquarter of each area how to get the
VERMEER. BIN file.

2. Loader Writing Permission Mode Setting

Note: This setting is unnecessary when no program is loaded to the flash
memory, or when "Loader Writing Permission Mode" is set already.
(Refer to "6. Check of Loader Writing Inhibit Mode".)
Setting method:
Order Page Address Data
1
0
01
2
7
01
3
7
02
4
7
04
5
7
05
6
7
06
7
7
00
8
7
02

3. Loading Method

1)
Remove the power supply of the camcorder.
2)
Inserts the Memory Stick Duo that memorizes the VERMEER.BIN
file to the memory stick slot.
3)
Connect the adjustment remote commander with the HOLD
switch set to the "ADJ" side.
4)
Connect the power supply to the camcorder.
5)
Check that the MS ACCESS LED is turned on for about 60
seconds. (The program is written in the flash memory in this
period.)
6)
Check that the MS ACCESS LED is turned off.
7)
Remove the Memory Stick Duo from the camcorder.
8)
Turn off the power and turn on again.
9)
Check that the camcorder is normal.
If normal, perform "4. Program Version Check" and "5. Loader
Writing Inhibit Mode Setting".
If the MS ACCESS LED is blinked, repeat from step 1).
Procedure
01
Set the data.
2F
Set the data, and press PAUSE
button.
FF
Set the data, and press PAUSE
button.
00
Set the data, and press PAUSE
button.
01
Set the data, and press PAUSE
button.
FF
Set the data, and press PAUSE
button.
01
Set the data, and press PAUSE
button.
Check that the data is "01".

4. Program Version Check

Order Page Address Data
1
5
FE
2
5
FF
Note: D
and D
are the program version.
FE
FF

5. Loader Writing Inhibit Mode Setting

Setting method:
Order Page Address Data
1
0
01
2
7
01
3
7
02
4
7
04
5
7
05
6
7
06
7
7
00
8
7
02
9
0
01

6. Check of Loader Writing Inhibit Mode

Checking method:
Order Page Address Data
1
0
01
2
7
01
3
7
02
4
7
03
5
7
04
6
7
05
7
7
00
8
7
02
9
7
03
10
0
01
6-8
Procedure
Read the data, and this data is
named D
.
FE
Read the data, and this data is
named D
.
FF
Procedure
01
Set the data.
2F
Set the data, and press PAUSE
button.
FF
Set the data, and press PAUSE
button.
00
Set the data, and press PAUSE
button.
01
Set the data, and press PAUSE
button.
20
Set the data, and press PAUSE
button.
01
Set the data, and press PAUSE
button.
Check that the data is "01".
00
Set the data.
Procedure
01
Set the data.
1F
Set the data, and press PAUSE
button.
FF
Set the data, and press PAUSE
button.
00
Set the data, and press PAUSE
button.
00
Set the data, and press PAUSE
button.
01
Set the data, and press PAUSE
button.
01
Set the data, and press PAUSE
button.
Check that the data is "01".
Check the data.
20: Loader writing inhibit mode
FF: Loader writing permission mode
00
Set the data.