Extron electronics DXP 1616 HD 4K PLUS Series Setup Manual page 13

Table of Contents

Advertisement

Command Function
Information Requests (continued)
Request part number
Query firmware version
Example:
Request system status
Example:
IP Setup
Set IP address
View IP address
Set subnet mask
View subnet mask
Set gateway IP address
View gateway IP address
Set DHCP on and off
View DHCP on/off status
Configure current port timeout
View current port timeout
Configure global IP port timeout
View global IP port timeout
Set verbose mode
NOTE:
If tagged responses is enabled (modes 2 and 3), all view commands return the constant string and the value as the set
command does (for example, the read matrix name command
View verbose mode
X1$
KEY:
= Total inputs
X1%
= Total outputs
X1^
= Voltage
X1&
= Internal temperature in degrees C
X1*
= Fan speed in RPM
X2!
= Firmware version number
X3^
= IP or Gateway address
X3&
= Subnet mask
X4^
=
DHCP status
X5#
=
Verbose mode
X5*
=
Port timeout interval
Reset
System reset to factory defaults
NOTE:
This command excludes IP settings such as IP address and subnet mask. It does not remove the file system.
Absolute system reset
NOTES:
This command includes resetting the IP address to 192.168.254.254 and the subnet mask to 255.255.0.0. The firmware
version remains the same.
The factory configured passwords for all accounts on this device have been set to the device serial number. In the event of
an absolute system reset, the passwords convert to the default, which is no password.
ASCII Command
Response
(Host to Switcher)
(Switcher to Host)
N
60
X2!]
Q
Q
1.23
X1^
S
S
12.127•27.062•2155
E X3^
}
CI
Ipi
E
}
X3^]
CI
E X3&
}
CS
Ips
E
}
X3&]
CS
E X3^
}
CG
Ipg
E
}
X3^]
CG
E X4^
}
DH
Idh
E
}
X4^]
DH
E
X5*
}
0*
TC
Pti0*
E
}
X5*]
0TC
E
X5*
}
1*
TC
Pti1*
E
}
X5*]
1TC
E X5#
}
CV
Vrb
E
E
}
X5#]
CV
Total number of inputs for this switcher
Total number of outputs for this switcher
Expressed to the second decimal place (n.nn)
nnn.nnn.nnn.nnn
nnn.nnn.nnn.nnn
0 = Disabled, 1 = enabled
0 = clear or none (default for Telnet connection)
1 = verbose mode (default for RS-232 and USB connection),
2 = tagged responses for queries, 3 = verbose mode and tagged for queries
1 (10 seconds) – 65000 (default is 30 = 300 seconds = 5 minutes)
E
}
ZXXX
Zpx
E
}
ZQQQ
Zpq
Additional Description
]
nnnn
01
-
-
View the unit firmware version.
]
The factory-installed firmware version is
1.23 (sample value only).
X1&
X1*]
Display power supply voltage
temperature
]
X3^]
Set the unit IP address to
View unit IP address.
X3&]
Set the subnet mask for the unit to
View the subnet mask.
X3^]
Set the unit gateway address to
View the unit gateway address.
X4^]
Set DHCP to
View the DHCP setting.
X5*]
Set the current port timeout to
View the current port timeout setting.
X5*]
Set the global IP port timeout to
View the global IP port timeout setting.
Set the verbose mode and tagged
X5#]
responses to
}
X3) ]
CN
, returns Ipn •
View the current verbose mode.
]
Clear all ties and presets and reset unit
to factory default settings.
]
Clear all ties and presets and reset unit
to factory default settings.
X1^
,
X1&
X1*
, and fan speed
X3^
.
X3&
X3^
X4^
.
X5*
.
X5*
X5#
.
).
.
.
.
.
13

Advertisement

Table of Contents
loading

Table of Contents