Cooling Charging Chart; Outdoor Coil, Indoor Coil And Condensate Drain Pan - Carrier 50ZH Series Installation, Start-Up And Service Instructions Manual

3-phase packaged heat pump
Hide thumbs Also See for 50ZH Series:
Table of Contents

Advertisement

40
50
SUCTION
LINE TEMPERATURE
gi-
11-
40
50
60
70
SUCTION LINETEMPERATURE
30
90
-1
4
10
16
21
27
32
SUCTION
LINE TEMPERATURE
0166
II
IllIII
._
.683
100-_
_
_
_
_:"
- -
UTDOORTEMP
=
,-11,--
oF
o c
46 -
_
_8 38 :
552 _80
CO
IIII
III1[
_70
55
13
--
483
__ _-J=N-H =
I_ll
11[1
|
1 Ell
]L
Io m+
:l:gA__
3451D50 _ _
_
_
_ _ _ _
CO
_ I _ I
III
I III
I
I111
I_[[I
1
Jl[ll
l[[llJl[
I I
I
I
11
III
I Ill
I
/
I
207
30
IIIll
Illlllll
I
I
I
I
I
I
I
30
40
50
60
70
80
90
164
SUCTION LINE TEMPERATURE (°F)
I
I
I
I
I
I
I
-1
4
10
16
21
27
32
o
SUCTION LINE TEMPERATURE (C)
C00165
Fig. 20--Cooling
Charging
Chart--50ZH042
Units
[ [Ll.L_I
II ..........................................
£[
1!
°F
°C II.
,1108
621 _'90-
E
_
95
35
_
_ 88 _
483552
_80-_70_
-
_-_-_
_!!i_
_
"'6521_75
55
24H_1318""
z60. i
348>o-
................
,q ,,,,,,
30.
30
40
50
60
70
80
90
SUCTION LINETEMPERATURE
-1
4
10
16
21
27
32
SUCTION LINE TEMPERATURE
(°C)
C00167
Fig. 22--Cooling
Charging
Chart--50ZH060
un ts
a. Lift
wheel from housing.
When handling
and/or cleaning
blower
wheel,
be sure not to disturb
balance
weights
(clips)
on blower
wheel vanes.
b. Remove
caked-on
dirt from
wheel
and
housing
with
a
brush.
Remove
lint and/or
dirt accumulations
l]'om wheel
and
housing
with
vacuum
cleaner,
using
a soft
brush
attachment.
Remove
grease
and oil with a mild solvent.
c. Reassemble
blower
into housing.
Place upper
orifice
ring
on blower
to judge
location
of the blower
wheel.
Blower
wheel
should
be approximately
0.2-in.
below
bottom
of
orifice
ring when centered
correctly.
Be sure setscrews
am
tightened
on motor and are not on round
part of shaft.
d. Set upper orifice
ring in place
with 3 screws
removed
in
step 1 above.
e. Replace
top access
paneh
Step
4--Outdoor
Coil,
Indoor
Coil,
and
Condensate
Drain
Pan
Inspect the outdoor
coil, indoor
coil, and condensate
drain pall at
least
once
beating
and
cooling
season.
Proper
inspection
and
cleaning
requircs
the
removal
of the
unit top.
See
Unit
Top
Removal
section
abole.
Remove
all obstructions
(including
weeds
and shrubs)
that inter-
Ibm with the airflow
through
the outdoor
coil. Straighten
bent fins
with a fin conlb.
If coated
with dirt or lint, clean the coils with a
vacuum
cleaner,
using
a soft brush
attachment.
Be careful
not to
bend the l]ns. If coated
with oil or grease,
clean the coils
with a
mild detergent-and-water-solution.
Rinse
coils
with
clear
water,
using
a garden
hose.
Be carclM
not to splash
water
on motors,
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

50zh03050zh03650zh04250zh04850zh060

Table of Contents