ExtremeSwitching SLX 9540 Technical
Specifications
System specifications
System component
Enclosure
Power supplies
Fan assemblies
Cooling
System architecture
System processors
Ethernet
System component
QSFP-28 ports
SFP+ ports
Ethernet management port
LEDs
System component
Interface module LEDs
Power supply LEDs
ExtremeSwitching SLX 9540 Hardware Installation Guide
9036360-00 Rev AB
Description
Chassis-mountable on a desktop, or in a standard 2 or 4-post rack kit
Dual redundant, hot-swappable power supplies supported with 650 W AC intake or exhaust airflow, or 650 W
DC intake or exhaust airflow.
Up to five redundant, hot-swappable fan units with intake or exhaust airflow
Forced-air cooling front-to-back or back-to-front
Non-blocking shared-memory switch
Control path based on Intel Broadwell-DE. CPU 4-cores, 8-threads running at 2.2 GHz, 35W
Data path based on Broadcom DUNE chipsets, Qumran MX (BCM8837x) - Broadcom packet processor and
traffic manager
Description
The QSFP-28 ports can support 100GbE/40GbE natively and 10GbE/25GbE through
breakout cables. There are 6 x 100GbE ports.
The SFP+ ports can support 10GbE/1GbE interfaces. There are 48 x SFP+ ports.
RJ-45 port with 10/100/1000 Mbps auto-negotiating capability
Description
•
Power: Green - Power OK, off - No power
•
Status: Green- Status OK, Amber - Error; Off - Unexpected error
•
Link status (1 LED per physical port): Green (Solid) - Link is up; Green (Blinking rapidly) - Link is up
and running traffic; Green (Blinking on and off for two seconds at a time) - Local fault detected; Off -
No link
•
LED 1 and LED 2: Steady Green - Input and output voltages are within range
•
LED 1: Off and LED 2: Flashing Yellow - Power supply does not have incoming power and is not
providing power to the device, or the Input AC voltage is out of range.
•
LED 1: Green and LED 2: Yellow - Output voltage is out of range
•
LED 1: Green and LED 2: Flashing Yellow/Green - Over-temperature warning or fan error
Maximum ports
supported
6
48
1